Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 77 (2000), S. 4040-4042 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: We describe a design for bolometric detectors of infrared and mm-wave radiation produced in large-format filled arrays by standard planar lithography. A square grid of metallized silicon nitride absorbs the radiation. The bolometer suspension, sensor, and wiring occupy a small fraction of the area. We have produced a 1024 element array of fully released and suspended 1.5 mm×1.5 mm bolometer micromeshes with a filling factor of 88%. We describe a voltage-biased superconducting bolometer built as a prototype for one array element. We have measured noise equivalent power =2.3×10−17 W/Hz, τ=24 ms, and G=2.7×10−11 W/K at 304 mK. © 2000 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 78 (2001), S. 371-373 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: We present the design and experimental evaluation of a superconducting quantum interference device (SQUID) multiplexer for an array of low-temperature sensors. Each sensor is inductively coupled to a superconducting summing loop which, in turn, is inductively coupled to the readout SQUID. The flux-locked loop of the SQUID is used to null the current in the summing loop and thus cancel crosstalk. The sensors are biased with an alternating current, each with a separate frequency, and the individual sensor signals are separated by lock-in detection at the SQUID output. We have fabricated a prototype 8 channel multiplexer and discuss the application to a larger array. © 2001 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 38 (2000), S. 175-179 
    ISSN: 1741-0444
    Keywords: Microelectrodes ; Neurophysiology ; Silicon-micromachining ; Neurotechnology
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract A process is described for the fabrication of silicon-based microelectrodes for neurophysiology using bonded and etched-back silicon-on-insulator (BESOI) wafers. The probe shapes are defined without high levels of boron doping in the silicon; this is considered as a step towards producing probes with active electronics integrated directly beneath the electrodes. Gold electrodes, of 4μm by 4μm to 50μm by 50μm are fabricated on shanks (cantilever beams) 6μm thick and which taper to an area approximately 100μm wide and 200μm long, which are inserted into the tissue under investigation. The passive probes fabricated have been successfully employed to make acute recordings from locust peripheral nerve.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...