Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 2000-2004  (8)
Material
Years
Year
  • 1
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Introduction: The implantable cardioverter defibrillator (ICD) is commonly used to treat patients with documented sustained ventricular tachycardia (VT) or ventricular fibrillation (VF). Arrhythmia recurrence rates in these patients are high, but which patients will receive a therapy and the forms of arrhythmia recurrence (VT or VF) are poorly understood. Methods and Results: The therapy delivered by the ICD was examined in 449 patients randomized to ICD therapy in the Antiarrhythmics Versus Implantable Defibrillators (AVID) Trial. Events triggering ICD shocks or antitachycardia pacing (ATP) were reviewed for arrhythmia diagnosis, clinical symptoms, activity at the onset of the arrhythmia, and appropriateness and results of therapy. Both shock and ATP therapies were frequent by 2 years, with 68% of patients receiving some therapy or having an arrhythmic death. An appropriate shock was delivered in 53% of patients, and ATP was delivered in 68% of patients who had ATP activated. The first arrhythmia treated in follow-up was diagnosed as VT (63%), VF (13%), supraventricular tachycardia (18%), unknown arrhythmia (3%), or due to ICD malfunction or inappropriate sensing (3%). Acceleration of an arrhythmia by the ICD occurred in 8% of patients who received any therapy. No physical activity consistently preceded arrhythmias, nor did any single clinical factor predict the symptoms of the arrhythmia. Conclusion: Delivery of ICD therapy in AVID patients was common, primarily due to VT. Inappropriate ICD therapy occurred frequently. Use of ICD therapy as a surrogate endpoint for death in clinical trials should be avoided. (J Cardiovasc Electrophysiol, Vol. 14, pp. 940-948, September 2003)
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of cardiovascular electrophysiology 11 (2000), S. 0 
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Ventricular Tachycardia Ablation, Introduction. Sustained monomorphic ventricular tachycardia (VT) associated with nonischemic cardiomyopathy (CMP) is uncommon. Optimal approaches to catheter mapping and ablation are not well characterized, but they are likely to depend on the VT mechanism. The purpose of this study was to evaluate the mechanisms of sustained monomorphic VT encountered in nonischemic CMP and to assess the feasibility, safety, and efficacy of catheter radiofrequency ablation for treatment. Methods and Results: Twenty-six consecutive patients with nonischemic CMP referred for management of recurrent VT were studied. In 16 (62%) patients, VT was related to a region of abnormal electrograms consistent with scar and the response to pacing suggested a reentrant mechanism. In 5(19%) patients, VT was due to bundle branch or interfascicular reentry. In 7(27%) patients, the VT mechanism was focal automaticity, 4 of whom had evidence of tachycardia-induced CMP. After catheter ablation targeting parts of reentrant circuits, VT was not inducible in 8 (53%) of 15 patients with scar-related reentry, was modified in 5(33%) patients, and still was inducible in 2(13%) patients. Ablation was successful in 5 of 5 patients with bundle branch reentry and in 6 of 7 patients with a focal automaticity mechanism. Overall, catheter ablation abolished clinical recurrence of VT in 20 (77%) of 26 patients during a follow-up of 15 ± 12 months. Conclusion: Three different mechanisms of VT are encountered in patients with nonischemic CMP. The mapping and ablation approach varies with the type of VT. In this selected population, the overall efficacy was 77%.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of cardiovascular electrophysiology 11 (2000), S. 0 
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Ablation of Unstable Ventricular Tachycardia. Introduction: Hemodynamic collapse precludes extensive catheter mapping to identify focal target regions in many patients with ventricular tachycardia (VT) associated with heart disease. This study tested the feasibility of catheter ablation of poorly tolerated VTs by targeting a region identified during sinus rhythm. Methods and Results: Ablation was attempted in five patients, ages 44 to 59 years, with left ventricular ejection fractions of 0.15 to 0.20 and poorly tolerated VT causing multiple implantable defibrillator therapies (6 to 30 episodes/month). VT was due to prior infarction in three patients and nonischemic cardiomyopathy in two. Target regions were sought that met the following criteria: (1) evidence of slow conduction from fractionated sinus rhythm electrograms and stimulus-QRS delays during pace mapping, and (2) evidence that the region contains the reentrant circuit exit from pace mapping. In 4 of 5 patients, a target region was identified and radiofrequency lesions applied. Ablation abolished all recurrences of VT in 3 of 4 patients during follow-up of 14 to 22 months. There were no complications. Conclusion: Ablation of poorly tolerated VT is feasible in some patients by mapping during sinus rhythm and performing ablation over a region of identifiable scar that contains abnormal conduction and a presumptive VT exit.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148-5018 , USA , and 9600 Garsington Road , Oxford OX4 2DQ , UK . : Blackwell Futura Publishing, Inc.
    Pacing and clinical electrophysiology 26 (2003), S. 0 
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Methods for determining if an ablation lesion has been created by RF current application are limited, but needed. This study sought to determine if a change in pacing threshold at the ablation site might be used to assess creation of an ablation lesion. Peak-to-peak amplitude of the bipolar electrogram (EGM) and the unipolar pacing threshold were determined before and after creation of RF lesions using irrigated tip (63 lesions in 11 patients) or conventional ablation catheters (33 lesions in 9 patients) in infarct scars for ablation of ventricular tachycardia. The threshold was measured during continuous pacing at a cycle length of 600 ms by a decrementing output current at a pulse width of 2 ms. The unipolar pacing threshold increased by 254 ± 248% (from 5.7 ± 3.5 to 15.1 ± 6.7 mA, P 〈 0.001 ) after irrigated tip ablation and by 155 ± 144% (from 5.9 ± 3.4 to 12.3 ± 5.7 mA, P 〈 0.001 ) after conventional ablation ( P 〈 0.05 for irrigated tip vs conventional). EGM amplitude decreased by 17 ± 27% (from 0.39 ± 0.32 to 0.30 ± 0.21 mV ) after irrigated tip ablation and by 16 ± 24% (from 0.48 ± 0.27 to 0.41 ± 0.20 mV ) after conventional ablation (irrigated tip vs conventional, P = NS). There was no correlation between the change in bipolar EGM amplitude and the pacing threshold. An increase in unipolar pacing threshold is a marker of lesion creation. In regions of infarction, the relative change in threshold produced by ablation is substantially larger than the change in bipolar electrogram amplitude. The greater increase in pacing threshold after irrigated tip ablation compared to conventional ablation suggests that the magnitude of change reflects lesion size. (PACE 2003; 26:1993–1996)
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: DELACRETAZ, E., et al.: Single Catheter Determination of Local Electrogram Prematurity Using Simultaneous Unipolar and Bipolar Recordings to Replace the Surface ECG as a Timing Reference. Bipolar recordings eliminate much of the far-field signal, while minimally filtered unipolar recordings contain substantial far-field signal components. These properties may allow the onset of the unipolar recording to serve as a timing reference for the bipolar recording obtained from the same electrode catheter during mapping of focal atrial or ventricular tachycardias. Mapping and RF ablation were performed in 26 patients with focal ventricular tachycardia and 14 patients with focal atrial tachycardia. At 205 mapping sites, simultaneous recordings of (1) minimally filtered unipolar electrograms (0.5–500 Hz), (2) high pass filtered unipolar electrograms (100 Hz), and (3) filtered bipolar recordings (30–500Hz) were analyzed. The interval between the onset of the minimally filtered unipolar electrogram and the first peak of the bipolar electrogram (UniOn - Bip) correlated closely with the timing of the local electrogram referenced to the surface ECG (r = 0.85, P 〈 0.001). Of 53 sites where RF ablation was performed, UniOn - BiP was shorter at successful compared to unsuccessful sites (3.8 ± 3.5 vs 9.2 ± 5.2ms, P 〈 0.001) and was 〈 15 ms at all successful sites. In conclusion, the comparison of simultaneous unipolar and bipolar electrograms from a single catheter allows assessment of the prematurity of local electrograms from a focal source without the use of the P wave or QRS onset as a timing reference.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: General modalities of analyses that have, been used for ICD studies are reviewed. Published “typical” examples are briefly described. The historical cohort method is exemplified with previously unpublished data from the Seattle Cardiac Arrest Survivor database. The AVID Study database is used to compare the results obtained from nonrandomized methodologies with randomized methodologies. Particular issues related to the use of the ICD for example, mode of death, inability to blind, selection practice, and treatment decision times make this a natural pedagogic platform.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Cardiac electrophysiology review 4 (2000), S. 240-242 
    ISSN: 1573-725X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗