Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (37)
  • 1990-1994  (52)
  • 1965-1969  (5)
  • 1
    Electronic Resource
    Electronic Resource
    College Park, Md. : American Institute of Physics (AIP)
    The Journal of Chemical Physics 111 (1999), S. 11216-11221 
    ISSN: 1089-7690
    Source: AIP Digital Archive
    Topics: Physics , Chemistry and Pharmacology
    Notes: Dynamic light scattering data on a polymer gel electrolyte with a complex relaxation behavior is presented. The electrolyte consists of lithium perchlorate dissolved in an ethylene carbonate and propylene carbonate solution that is immobilized with poly(methyl methacrylate). We attribute the observed relaxation processes to two diffusive and one segmental relaxation processes based on the form of the time decay of the intermediate scattering function and the corresponding temperature and wave vector dependencies. The dynamic light scattering results are compared with the ionic conductivity, which reveals a close connection between the fast diffusive motion of the low molecular weight solvent within the gel and the ionic conductivity. This motion is strongly decoupled from and considerably faster than the segmental motion of the polymer matrix. The results indicate that the ionic transport occurs mainly within the low molecular weight solvent. © 1999 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Psychophysiology 30 (1993), S. 0 
    ISSN: 1469-8986
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine , Psychology
    Notes: Positron emission tomographic measurements of regional cerebral blood flow (rCBF) were used to investigate central nervous system correlates of fear and anxiety. Volunteers with symptomatic snake phobia were studied while exposed to visual phobogenic, aversive, and neutral stimuli. Anxiety ratings and the number of nonspecific electrodermal fluctuations increased as a function of phobic stimulation. Phobic, compared to neutral and aversive, stimulation elevated rCBF in the visual associative cortex. The basal ganglia were not activated more by phobic than aversive or neutral stimulation. However, cortical and thalamic rCBF were always correlated during phobic but not aversive or neutral stimulation. This indicates that the thalamus could be a relay station for phobic stimulus processing and affect.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1520-4995
    Source: ACS Legacy Archives
    Topics: Biology , Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 65 (1994), S. 3587-3588 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: An intense supersonic beam of atomic fluorine has been generated using nozzles fabricated from single-crystal CaF2 and MgF2. The latter material has been tested up to 1000 °C with no observable damage. This is (approximately-greater-than)250 °C hotter than previously achieved, increasing the atomic beam intensity by (approximately-greater-than)5×.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A battery-operated portable synchronous luminescence spectrofluorometer was developed for on-site analysis of groundwater or hazardous waste sites. The instrument is capable of either emission, excitation, or synchronous fluorescence measurements. The instrument is suited for trace analysis of important pollutants such as polyaromatic hydrocarbons, creosotes, and polychlorinated biphenyls in complex mixtures. The ability to perform synchronous luminescence measurements on these samples can reduce the complexity of fluorescence spectra and help in rapid field site characterization. A description of the instrumental components is given and an evaluation of the instrument using anthracene and several oil samples is provided to illustrate the usefulness of the instrument.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 70 (1999), S. 1684-1687 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The TGV32, a 32-channel preamplifier–multiplicity discriminator chip for the multiplicity vertex detector (MVD) at PHENIX, is a unique silicon preamplifier in that it provides both an analog output for storage in an analog memory and a weighted summed-current output for conversion to a channel multiplicity count. The architecture and test results of the chip are presented. Details about the design of the preamplifier, discriminator, and programmable digital–analog converters performance as well as the process variations are presented. The chip is fabricated in a 1.2 μm, n-well, complementary metal–oxide–semiconductor process. © 1999 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 69 (1998), S. 377-383 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A photospectrometer has been realized in a standard integrated circuit (IC) process. Only the masks, materials, and fabrication steps inherent to this IC process were used (i.e., no post processing to add mechanical or optical devices for filtering). The spectrometer was composed of a set of 18 photodetectors with independent spectral responses. The responses of these devices were weighted and summed to form outputs proportional to the input optical power in discrete wavelength bands in the region from ∼400 to ∼1100 nm. With the solution space restricted to a 60 nm band, this instrument could resolve Gaussian input spectra (σ=5 nm) with a peak-to-peak spacing of less than 15 nm. This device could easily be integrated with additional analog, digital, or wireless circuits to realize a true laboratory instrument on-a-chip. © 1998 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 68 (1990), S. 5840-5844 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: In order to test the statistical influence of some process and micromachining parameters on the fracture strength of silicon microelements, arrays of identical microsized cantilever beams were bulk micromachined in single-crystalline silicon wafers. The beams were exposed to various surface treatments (diamond polishing with different grades, oxidization, stripping of oxide) in different combinations. The influence on fracture strength was investigated by bending the beams to fracture in a micromanipulator mounted in situ in a scanning electron microscope while registering force-versus-deflection curves. Average fracture strengths, standard deviations, Weibull moduli, crack-initiating flaw sizes, and in some cases elastic moduli were evaluated. Diamond polishing was found to decrease the fracture strength drastically, but polishing followed by oxidization not only restored the original strength, but actually increased it, due to crack healing. Polishing, oxidization, and subsequent stripping of oxide resulted in fracture strengths slightly higher than the original strength. The Weibull modulus was diminished from 10 to 6–9 by the polishing. The initiating flaw sizes were theoretically evaluated, and found to agree with previous results of cross-sectional transmission electron microscopy studies of polished silicon surfaces. The elastic moduli determined were significantly lower (30%–40%) than the corresponding module of pure, single-crystalline silicon, probably due to high dopant contents in the specimens investigated here.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 69 (1991), S. 2097-2104 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: A special stress relaxation effect in thin aluminum films evaporated onto oxidized silicon wafers is reported. The effect is observed at elevated temperature and under tensional stress. It appears as if certain Al grains in the film surface suddenly "collapse'' compared to surrounding grains. The phenomenon is observed during the cooling phase of an annealing cycle, or when imposing external strain on the film by bending of the substrate at elevated temperature. Such external strain was imposed by micromechanical technique in situ in a scanning electron microscopy (SEM), and the collapse phenomenon was monitored as it happened. The phenomenon occurred instantaneously and only in films of thickness 1 μm or more; thinner films relaxed by hole formation. The grain collapse effect is characterized, and a physical explanation is given, supported by SEM and transmission electron microscopy (TEM) investigations and surface profile measurements.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Analytical chemistry 63 (1991), S. 1789-1794 
    ISSN: 1520-6882
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...