Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (12)
  • 1990-1994  (13)
  • 1950-1954
  • Polymer and Materials Science  (21)
  • Fenoterol  (2)
  • Intraclass correlation  (2)
  • 1
    ISSN: 1432-1041
    Keywords: Hypokalaemia ; Fenoterol ; Salbutamol ; exercise
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Abstract Objective: The effect of β2-adrenoceptor agonist-induced hypokalaemia on cardiac arrhythmias might be exacerbated during exercise, especially in patients with more compromised airway function. Methods: To evaluate the effect of β2-adrenoceptor agonists on plasma potassium and cardiopulmonary function during exercise, two identical submaximal treadmill exercise tests were performed, at least 48 h apart, by 13 patients with moderate to severe COPD (11 men and 2 women, mean age 66 y, mean FEV1/FVC ratio 48.9 (2.8)%) 30 min after they had received nebulised fenoterol or salbutamol (2 mg). The experiment was done as a randomised, double-blind, crossover trial after an initial baseline study with vehicle (0.45% saline). Plasma potassium concentration, spirometry and the degree of breathlessness (Borg scale) were measured before treatment and immediately after exercise; oxygen saturation, QTc interval and cardiac rhythm were monitored continuously before, during and for 30 min after exercise. Results: After the saline control, exercise caused an increase in Borg rating (of 4.9), a premature ventricular contractions (VPC) (2.8 beats/min), and a fall in oxygen saturation (-6.7%), but no significant change in plasma potassium (+0.04 mEq·dl−1), FEV1 or QTc interval. Inhalation of fenoterol and salbutamol did not affect QTc interval, Borg scale or VPC frequency at rest, but significantly increased the duration of exercise undertaken to reach the submaximal levels (786 s, versus 783 s) compared to the vehicle control. Following exercise, plasma potassium fell after fenoterol by 0.2 mEq·dl−1 and it increased after salbutamol by 0.1 mEq·dl−1 compared to baseline levels. Plasma potassium after exercise was significantly lower after fenoterol (3.2 mEq·dl−1) compared to the saline control (3.7 mEq · dl−1) and salbutamol (3.6 mEq · dl−1). Neither fenoterol nor salbutamol had any significant effect on the change in FEV1, oxygen saturation, Borg scale, frequency of VPCs or QTc interval during or after exercise compared to the saline control. Conclusion: When compared to salbutamol 2 mg, fenoterol 2 mg caused more marked hypokalaemia but no significant difference in cardiopulmonary response in patients with COPD during exercise.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1041
    Keywords: Key words Hypokalaemia ; Fenoterol ; Salbutamol; exercise
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Abstract Objective: The effect of β2-adrenoceptor agonist-induced hypokalaemia on cardiac arrhythmias might be exacerbated during exercise, especially in patients with more compromised airway function. Methods: To evaluate the effect of β2-adrenoceptor agonists on plasma potassium and cardiopulmonary function during exercise, two identical submaximal treadmill exercise tests were performed, at least 48 h apart, by 13 patients with moderate to severe COPD (11 men and 2 women, mean age 66 y, mean FEV1/FVC ratio 48.9 (2.8)%) 30 min after they had received nebulised fenoterol or salbutamol (2 mg). The experiment was done as a randomised, double-blind, crossover trial after an initial baseline study with vehicle (0.45% saline). Plasma potassium concentration, spirometry and the degree of breathlessness (Borg scale) were measured before treatment and immediately after exercise; oxygen saturation, QTc interval and cardiac rhythm were monitored continuously before, during and for 30 min after exercise. Results: After the saline control, exercise caused an increase in Borg rating (of 4.9), a premature ventricular contractions (VPC) (2.8 beats/min), and a fall in oxygen saturation (−6.7%), but no significant change in plasma potassium (+ 0.04 mEq⋅dl−1), FEV1 or QTc interval. Inhalation of fenoterol and salbutamol did not affect QTc interval, Borg scale or VPC frequency at rest, but significantly increased the duration of exercise undertaken to reach the submaximal levels (786 s, versus 783 s) compared to the vehicle control. Following exercise, plasma potassium fell after fenoterol by 0.2 mEq⋅dl−1 and it increased after salbutamol by 0.1 mEq⋅dl−1 compared to baseline levels. Plasma potassium after exercise was significantly lower after fenoterol (3.2 mEq⋅dl−1) compared to the saline control (3.7 mEq⋅dl−1) and salbutamol (3.6 mEq⋅dl−1). Neither fenoterol nor salbutamol had any significant effect on the change in FEV1, oxygen saturation, Borg scale, frequency of VPCs or QTc interval during or after exercise compared to the saline control. Conclusion: When compared to salbutamol 2 mg, fenoterol 2 mg caused more marked hypokalaemia but no significant difference in cardiopulmonary response in patients with COPD during exercise.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Theoretical and applied genetics 82 (1991), S. 421-424 
    ISSN: 1432-2242
    Keywords: Intraclass correlation ; Maximum likelihood estimator ; Bias
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Summary A bias correction was derived for the maximum likelihood estimator (MLE) of the intraclass correlation. The bias consisted of two parts: a correction from MLE to the analysis of variance estimator (ANOVA) and the bias of ANOVA. The total possible bias was always negative and depended upon both the degree of correlation and the design size and balance. The first part of the bias was an exact algebraic expression from MLE to ANOVA, and the corrected estimator by this part was ANOVA. It was also shown that the first correction term was equivalent to Fisher's reciprocal bias correction on hisZ scores. The total possible bias of MLE was large for small and moderate samples. Relative biases were larger for small parametric values and vice versa. To ensure a relative bias less than 10% assuming an intraclass correlation of 0.025, which is not unusual in most of the animal genetic studies, the total number of observations (N) should be not less than 500. From a design point of view, minimum bias occurred atn = 2, the minimum family size possible, underN fixed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Theoretical and applied genetics 85 (1992), S. 79-88 
    ISSN: 1432-2242
    Keywords: Intraclass correlation ; Negative estimate ; Restricted maximum likelihood
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Summary At least two common practices exist when a negative variance component estimate is obtained, either setting it to zero or not reporting the estimate. The consequences of these practices are investigated in the context of the intraclass correlation estimation in terms of bias, variance and mean squared error (MSE). For the one-way analysis of variance random effects model and its extension to the common correlation model, we compare five estimators: analysis of variance (ANOVA), concentrated ANOVA, truncated ANOVA and two maximum likelihood-like (ML) estimators. For the balanced case, the exact bias and MSE are calculated via numerical integration of the exact sample distributions, while a Monte Carlo simulation study is conducted for the unbalanced case. The results indicate that the ANOVA estimator performs well except for designs with family size n = 2. The two ML estimators are generally poor, and the concentrated and truncated ANOVA estimators have some advantages over the ANOVA in terms of MSE. However, the large biases may make the concentrated and truncated ANOVA estimators objectionable when intraclass correlation (ϱ) is small. Bias should be a concern when a pooled estimate is obtained from the literature since ϱ〈0.05 in many genetic studies.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part A: Polymer Chemistry 32 (1994), S. 2953-2960 
    ISSN: 0887-624X
    Keywords: benzobisthiazole ; bicyclo[2.2.2]octane ; rigid-rod ; colorless ; 3-dimensional ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Polycondensation in polyphosphoric acid of 2,5-diamino-1,4-benzene dithiol dihydrochloride with bicyclo[2.2.2]octane-1,4-dicarboxylic acid, as well as the corresponding dimethyl ester or diacid chloride, led to rigid-rod benzobisthiazole polymers. Colorless and soluble polymers with intrinsic viscosities as high as 30.6 dL/g (methanesulfonic acid, 30°C) were obtained. The ultraviolet-visible spectrum of a polymer film cast from methanesulfonic acid under reduced pressure displayed no absorptions in the visible range (400-900 °m). The polymer was thermooxidatively stable up to 420°C in air as determined by thermogravimetric analysis. Fibers spun from a lyotropic polyphosphoric acid solution exhibited a tensile strength of 300-450 Ksi, a modulus of 26 Msi, and a compressive strength of 53 Ksi. Wide-angle X-ray scattering patterns of polymer fibers indicated a 3-dimensional crystal structure rather than a nematic liquid crystal structure. © 1994 John Wiley & Sons, Inc.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part A: Polymer Chemistry 35 (1997), S. 3457-3466 
    ISSN: 0887-624X
    Keywords: PBO ; rigid-rod polymer ; multidimensional polymer ; compressive strength ; fiber morphology ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A high-torque rheometer was used to facilitate the polycondensation of 4-[5-amino-6-hydroxybenzoxazol-2-yl]benzoic acid (ABA) with trimesic acid and 1,3,5,7-tetrakis(4-carboxylatophenyl)adamantane to yield two- and three-dimensional benzobisoxazole polymers, respectively. Although the resultant polymer dopes exhibited improved homogeneity compared to polymer dopes previously prepared in glassware, improved polymer solution viscosities were not achieved. Fibers spun from the two- and three-dimensional polymers did not show a significant increase in compressive strength compared to fibers of the linear or one-dimensional benzobisoxazole polymer derived from the homopolymerization of ABA. Morphological studies of the polymer fibers and films by wide-angle X-ray scattering and scanning electron microscopy strongly indicated more lateral disorder and a more isotropic character for the three-dimensional structures compared to the one-dimensional structures. © 1997 John Wiley & Sons, Inc. J Polym Sci A: Polym Chem 35: 3457-3466, 1997
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part A: Polymer Chemistry 34 (1996), S. 2517-2519 
    ISSN: 0887-624X
    Keywords: functional polyester ; liquid/solid biphase polycondensation ; tertiary amine group ; heterogeneous polymer reaction ; quaternary ammonium group ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part A: Polymer Chemistry 34 (1996), S. 493-495 
    ISSN: 0887-624X
    Keywords: chemoselective polycondensation ; functional polymer ; aromatic polyester ; hydroxyl group ; sulfamino acid moiety ; amino acid moiety ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: No abstract.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Electroanalysis 2 (1990), S. 81-84 
    ISSN: 1040-0397
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A new nicotine sensor for the simple, rapid determination of nicotine in tobacco products without prior separation is described. The sensor is a coated graphite electrode with silicotungstic acid as the active material in polyvinyl chloride with di(2-ethylhexyl) phthalate as the plasticizer. At pH 5.5-6.0, it provides a Nernstian response to nicotine over 10-1 to 10-6 M; the detection limit is 7.4 × 10-7 M, and the average slope is 58 mV/pN. The analytical recovery is 98.1 to 102.3%. Satisfactory results are obtained in comparison with silicotungstate gravimetric method and UV spectrometry.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 0006-3525
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: We have used the molecular dynamics (MD) simulation package AMBER4 to search the conformation of a peptide predicted as a leucine zipper motif for the human immunodeficiency virus type I integrase protein (HIV IN-LZM). The peptide is composed of 22 amino acid residues and its location is from Val 151 to Leu 172. The searching procedure also includes two known α-helices that served as positive controls - namely, a 22-residue GCN4-p1 (LZM) and a 20-residue poly(L-alanine) (PLA). A 21-residue peptide extracted from a cytochrome C crystal (CCC-t) with determined conformation as a β-turn is also included as a negative control. At the beginning of the search, two starting conformations - namely, the standard right-handed α-helix and the fully stretched conformations - are generated for each peptide. Structures generated as standard α-helix are equilibrated at room temperature for 90 ps while structures generated as a fully stretched one are equilibrated at 600 K for 120 ps. The CCC-t and PLA helices are nearly destroyed from the beginning of equilibration. However, for both the HIV IN-LZM and the GCN4-p1 LZM structures, there is substantial helicity being retained throughout the entire course of equilibration. Although helix propagation profiles calculated indicate that both peptides possess about the same propensity to form an α-helix, the HIV IN-LZM helix appears to be more stable than the GCN4-p1 one as judged by a variety of analyses on both structures generated during the equilibration course. The fact that predicted HIV IN-LZM can exist as an α-helix is also supported by the results of high temperature equilibration run on the fully stretched structures generated. In this run, the RMS deviations between the backbone atoms of the structures with the lowest potential energy (PE) identified within every 2 ps and the structure with the lowest PE searched in the same course of simulation are calculated. For both the HIV IN-LZM and the GCN4-p1 LZM, these rms values decrease with the decrease of PE, which indicates that both structures are closer in conformations as their PEs are moved deeper into the PE well. © 1994 John Wiley & Sons, Inc.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...