Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Materialwissenschaft und Werkstofftechnik 29 (1998), S. 609-617 
    ISSN: 0933-5137
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Microstructural, mechanical and corrosive properties of friction stir welded aluminium jointsFriction stir welding (FSW) is a novel solid state welding process. It allows joining of high strength aluminum alloys, generally considered as difficult-to-weld with conventional technologies, without loss in joint strength. Results of investigations on selfmade FSW butt joints of the aluminum alloys 2024-T3 and 6013-T4 are presented. First, the microstructure of the weld seam and heat affected zone is characterised metallographically and by hardness measurements. By tensile, fatigue endurance (SN) and fatigue crack propagation tests it is demonstrated, that especially the FSW-joints of 2024-T3 sustain high mechanical loadings. Investigations on the corrosion properties reveal a certain sensitivity of the 2024-T3 joints to intergranular and exfoliation corrosion.
    Notes: Das Reibrührschweißen (friction stir welding FSW) ist ein neues Fügeverfahren, mit dem auch die schwer schmelzschweißbaren, höherfesten Aluminiumlegierungen ohne große Festigkeitsverluste verschweißt werden können. Erste Ergebnisse von Untersuchungen an selbst hergestellten FSW-Stumpfnähten der Aluminiumlegierungen 2024-T3 und 6013-T4 werden vorgestellt. Zunächst wird das Gefüge der Naht und der Wärmeeinflußzone mikrostrukturell und durch Härteverläufe charakterisiert. Weiterhin wird mit Zug-, Schwingfestigkeits- und Rißfortschrittsversuchen nachgewiesen, daß insbesondere die FSW-Nähte der Legierung 2024-T3 außerordentlich hohe mechanische Belastungen ertragen. Abschließende Korrosionsuntersuchungen der FSW-Nähte zeigen eine gewisse Anfälligkeit der abschreckempfindlichen Legierung 2024-T3 für interkristalline Korrosion und Schichtkorrosion.
    Additional Material: 15 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Chemie Ingenieur Technik - CIT 66 (1994), S. 1171-1171 
    ISSN: 0009-286X
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 24 (1990), S. 979-991 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: An experimental animal model was developed to investigate the release of metal ions from nonprecious dental alloys. Cast specimens of five Ni—Cr-alloys and Co—Cr-alloys were implanted intramuscularly in rabbits for periods of 2, 4, 8, and 12 weeks. The concentrations of nickel, chromium, cobalt, and molybdenum in the implantloaded muscles were determined by electrothermal atomic absorption spectrometry (AAS) and neutron activation analysis (NAA). Reference muscle samples of each animal were analyzed to determine the individual control values. Significant increases in the tissue concentrations of these metals occurred in the immediate vicinity of the implants. Concentration gradients of the corrosion products were found between the implant contact tissue and the implant periphery (p 〈 0.001). Tissue concentrations of nickel and chromium correlated (r 〈 0.7). Microprobe analysis before and after implantation of the alloy specimens indicated an even corrosive loss of the alloy surfaces and changes in the surface element distributions. Advantages and limitations of this animal model are discussed, as well as its application in future studies.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...