Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999
  • 1985-1989  (3)
  • Life and Medical Sciences  (2)
  • 65F10  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    BIT 29 (1989), S. 635-657 
    ISSN: 1572-9125
    Keywords: 65F10 ; Sparse matrices ; preconditioning ; ordering strategies ; conjugate gradients
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mathematics
    Notes: Abstract We investigate the effect of the ordering of the unknowns on the convergence of the preconditioned conjugate gradient method. We examine a wide range of ordering methods including nested dissection, minimum degree, and red-black and consider preconditionings without fill-in. We show empirically that there can be a significant difference in the number of iterations required by the conjugate gradient method and suggest reasons for this marked difference in performance. We also consider the effect of orderings when an incomplete factorization which allows some fill-in is performed. We consider the effect of automatically controlling the sparsity of the incomplete factorization through drop tolerances and level of fill-in.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Cellular Physiology 138 (1989), S. 115-120 
    ISSN: 0021-9541
    Keywords: Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: The basic fibroblast growth factor (FGF) is a potent mitogen that has vascular endothelium as one of its principle target cells. Recent work has provided both the complete amino acid sequence of basic FGF and the nucleotide sequence of the genes for both human and bovine basic FGF. Although capillary endothelial cells have been shown to produce basic FGF in vitro and to deposit basic FGF in their extracellular matrix in vitro as well, no direct evidence yet exists for the distribution of basic FGF in vivo. Antipeptide antibodies were prepared against a 15-amino-acid sequence from the amino terminus of basic FGF in order to avoid cross-reactivity with acidic FGF, a protein with 55% overall homology to basic FGF. After affinity purification, these antisera were used to localize the basic fibroblast growth factor in the fetal and adult bovine retina. Immunoreactive material was found in capillaries of the inner nuclear layer, a capillary network undergoing development during the third trimester in the fetal bovine eye. Although the resolution of the technique does not permit a unique assignment of cellular localization, the presence of stain immediately adjacent to the lumen of capillaries suggests that capillary endothelial cells may produce the basic fibroblast growth factor in vivo during vascular development.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 6 (1985), S. 177-188 
    ISSN: 0197-8462
    Keywords: microwave irradiation ; specular microscopy ; monkey ; corneal endothelium ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Both eyes of anesthetized cynomolgus monkeys (Macaca fascicularis) were irradiated with 2.45-GHz microwaves, either pulsed or continuous wave. In vivo corneal endothelial abnormalities were observed by specular microscopy and confirmed through histologic techniques after a 16- to 48-hour postexposure period. Pulsed microwaves with an average power density of 10 mW/cm2 (equivalent to a specific absorption rate (SAR) = 2.6 W/kg) produced these effects, while levels of 20-30 mW/cm2 (equivalent to a SAR = 5.3 to 7.8 W/kg) with continuous wave irradiation were required to produce similar changes.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...