Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (2)
  • 1985-1989
  • 74.76  (1)
  • 81.70  (1)
  • Chest X-ray  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    European radiology 7 (1997), S. 57-60 
    ISSN: 1432-1084
    Keywords: Key words: Pleural effusion ; Chest X-ray ; Sonography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. Diagnosis of pleural effusion (PE) on supine chest X-ray (SCXR) is considered difficult. This study aimed at evaluating the accuracy of the diagnosis of PE on SCXR and was performed in two phases. At phase 1, a formula for the sonographic estimation of the volume of PE was established by correlating 24 measurements (in 7 patients in whom complete drainage was achieved) with the drained volumes. At phase two, 112 consecutive SCXRs were supplemented by sonography of the chest. The films were evaluated for the presence of PE and for the presence of different radiologic signs of PE. Sonography showed PE in 41 right and 30 left hemithoraces. The overall accuracy of the diagnosis of PE on SCXR was 82 %. Only one of the undiagnosed PEs had a volume of 〉 300 ml. The most accurate signs were increased density of the hemithorax, blunted costophrenic angle, and loss of the hemidiaphragm silhouette.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Journal of low temperature physics 106 (1997), S. 493-502 
    ISSN: 1573-7357
    Keywords: 74.50 ; 74.76 ; 87.40 ; 81.70
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract We describe the design and fabrication of thin-film Nb gradiometers with integrated DC SQUIDs for use in non-destructive evaluation (NDE) and biomagnetism. Issues of sensitivity, imbalance and field response are considered. Results are presented from eddy-current NDE in an unshielded environment of aluminium plates with sub-surface flaws, and from biomagnetic measurements of spinal and peripheral nerve evoked fields.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...