Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-2161
    Keywords: Key words Skeletal metastases ; PET ; Fluoride ; CT
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract  Objective. To characterise the uptake of 18F in skeletal metastases from breast cancer using positron emission tomography (PET) and to relate these findings to the appearance on CT. Patients and design. PET with 18F and CT were performed in five patients with multiple skeletal metastases from breast cancer. The CT characteristics were analysed in areas with high uptake on the PET study. Dynamic PET imaging of the skeletal kinetics of the 18F-fluoride ion were included. Results. The areas of abnormal high accumulation of 18F correlated well with the pathological appearance on CT. Lytic as well as sclerotic lesions had markedly higher uptake than normal bone, with a 5–10 times higher transport rate constant for trapping of the tracer in the metastatic lesions than in normal bone. Conclusion. PET with 18F-fluoride demonstrates very high uptake in lytic and sclerotic breast cancer metastases.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 28 (1986), S. 100-104 
    ISSN: 1432-1920
    Keywords: Stereotaxic techniques ; Brain imaging ; Angiography ; Radiography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary A method for the determination of stereotaxic coordinates in radiography, e.g. angiography, pneumoencephalography or digital vascular radiography, is described. A special localization frame containing radiopaque structures and scales defines a diagnostic coordinate system. This frame is fixed to the X-ray-table prior to the radiographic procedure and two projections are obtained at arbitrary angles to each other. The focus-film distances do not how to be fixed. The target coordinates are then determined either by a simple graphical procedure or with the use of a digitizing x-y-table, by a computer. With the computer method the films are placed on the digitizing table and the target and a few reference points are marked using a cursor. From the relative positions the computer calculates the coordinates. With the special head fixation system, coordinates of structures visualized in radiographic examinations can be transferred to various therapeutic or diagnostic stereotaxic devices.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...