Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Vitamin B and C in tablets ; Experimental design ; Optimization of separation ; Multiple regression modeling
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The ion-pair liquid-chromatographic separation of the water-soluble vitamins thiamine mononitrate, riboflavin phosphate, nicotinamide, pyridoxine hydrochloride, ascorbic acid, saccharin, and the dye Sunset Yellow FCF (E110) has been examined for the analysis of the compounds in effervescent tablets. A Draper-Lin small composite design was used to study the impact on the compounds' retention times and peak-widths (the response variables) of four different mobile phase variables: percentage of methanol as organic modifier, the concentrations of hexanesulfonate as ion pairing reagent and of triethanolamine as competitive base, and pH. The interactions of these variables were also studied. The proposed design enabled derivation of multiple linear regression equations to model each compound's retention time and peak-width at half-height. The statistical reliability of the regression models was established by comparing predicted and experimental values. By introducing the regression models into a spreadsheet program (Excel 5.0), retention times and peak-widths for each compound were calculated at fixed mobile phase pH. The values of all the other combinations of the three mobile phase variables were changed in increments of two units within their examined boundaries, resulting in 225 different rows. For each combination the compounds' calculated retention times and their corresponding peak-widths were sorted in increasing order and the resolution between successive peaks was calculated. The minimum effective resolution (R s min) between each pair of peaks and the maximum retention time (t R max) in each row were then selected and used to construct contour plots indicating the location of zones of mobile phase parameter combinations whereR s min〉1.5 and the analysis was rugged, and wheret R max values were minimum. Their common regions resulted in optimum chromatographic separations. Examples are shown of chromatographic separations obtained using mobile phase combinations which were the best compromise of the three criteria selected.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...