Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (1)
  • 1970-1974  (1)
  • Analytical Chemistry and Spectroscopy  (1)
  • Polymer and Materials Science
  • 1
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: Commercial gas chromatography quadrupole ion-trap mass spectrometer (GC/ITMS) instruments have been used in a novel way for the study of negative ions formed from perfluorotributyl-amine and polychlorinated biphenyl compounds. Negative ions, formed during a normal electron impact ionization period in which 70 eV electrons were used, were isolated in an ion trap by the application of a negative DC voltage to the ring electrode that caused all positive ions to be ejected from the ion trap; in the subsequent analytical scan, negatives ions were detected with an electron multiplier biased normally so as to detect positive ions. The major negative-ion species detected from FC-43 were m/z 252 to m/z 633; 34 other negative-ion species were detected also, though in low abundance. The observed negative-ion mass range extended from m/z 252 to m/z 633. The signal-to-noise ratio of negative-ion mass spectra was enhanced by operation of the GC/MS instrument in GC mode and averaging the mass spectra acquired. In an examination of 3 hexachlorobiphenyl compounds, the molecular anion cluster around m/z 360 for the non-ortho-substituted congener 169 was observed with a signal-to-noise ratio of ca. 20 for 90 pg injected on column: the response for congener 169 was greater than that for congener 156 (mono-ortho-substituted) which, in turn, was greater than that for congener 153 (di-ortho-substituted).
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 15 (1971), S. 835-851 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: A typical gas chromatogram of the volatile pyrolysis products of untreated α-cellulose contains 39 peaks; however, mass spectral data indicate that at least 59 compounds, with molecular weights less than about 150, are present. A total of 37 compounds have been identified, 13 of which have not been previously reported. Most of the newly identified compounds contain a benzene ring, indicating that these compounds may be products of reactions between initial volatiles. A comparison of the products generated in the temperature range of 330°-440°C indicates that the formation of pyrolysis products is essential independent of temperature. Comparisons of the chromatograms obtained for untreated levoglucosan and cellulose indicate that most of the decomposition of cellulose probably forms levoglucosan which then decomposes to yield the observed pyrolysis products. In addition, the products of flame retardant-treated levoglucosan are essentially the same as those of cellulose with the same retardant treatment. This suggests that the retardants act on the levoglucosan formed in the decomposition of the cellulose rather than on the cellulose directly.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...