Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of cardiovascular electrophysiology 10 (1999), S. 0 
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Parasympathetic Stimulation via Intracardiac Shocks. Introduction: In patients receiving test shocks to verify lead connections at implantation, we anecdotally have observed postshock delay. The purpose of this study was to determine whether QRS-synchronous low-energy shocks delivered by implantable defibrillators result in postshock cycle length prolongation, and to determine the mechanism of this phenomenon. Methods and Results: Twenty-five patients undergoing defibrillator testing were studied, three with epicardial patches and 22 with transvenous leads. Each patient received QRSsynchronous shocks of 0.2, 0.4, 0.6, and 2.0 J in random order. Patients were further randomized to receive either saline or 2.0 mg atropine intravenously, and then given a second sequence of shocks. At baseline, the postshock cycle length (1, 035 ± 245 msec) was significantly longer than the preshock cycle length (968 ± 177 msec, P = 0.01). In patients with a coronary sinus (CS) or superior vena cava (SVC) lead, the mean prolongation was 91 ± 160 msec, compared with 12 ± 106 msec for patients without such a lead (P 〈 0.0001). All energy levels resulted in significant postshock prolongation compared with preshock cycle lengths (P 〈 0.05). Postshock prolongation before atropine was 76 ± 162 msec, compared with −13 ± 52 msec afterward (P 〈 0.00001). Biphasic shocks resulted in greater postshock prolongation than monophasic shocks of equal energy. Conclusion: Low-energy shocks delivered during the QRS complex cause postshock cycle length prolongation in man. This effect required the presence of a CS or SVC lead. Atropine inhibited this effect, suggesting the phenomenon was mediated by direct cardiac parasympathetic nerve stimulation by the intracardiac shock.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of chemical & engineering data 17 (1972), S. 412-415 
    ISSN: 1520-5134
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of fish biology 51 (1997), S. 0 
    ISSN: 1095-8649
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Biology
    Notes: The advantages and disadvantages of various numerical and graphical techniques for the analysis of inter- and intraspecific feeding relationships of fishes were examined. All methods have been cited in the literature since 1988. The index of preponderance, the resultant index and graphical methods proposed by Costello and Tokeshi were used to illustrate the relative importance of prey species to an individual fish species with no differentiation between size classes. Inter- and intraspecific competition and niche overlap were determined from multivariate analysis [the ordination technique, detrended correspondence analysis, cluster analysis by the Bray-Curtis equation, per cent overlap and two-way indicator species analysis (TWINSPAN)]. The identity of the prey organisms are not lost in the comparisons, and the value of this is determined through comparison with techniques such as Shannon-Wiener which obscure these data. The Shannon-Wiener diversity index was combined with an analysis of ‘evenness’ to refine the technique further to assess niche breadth, as was the Levins index. The study shows that to give an estimate of competition within the community, it is important to assess the data with respect to seasonal and temporal patterns using multivariate analysis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    facet.materialart.
    Unknown
    London : Periodicals Archive Online (PAO)
    Journal of theological studies. n.s.:23 (1972) 322 
    ISSN: 0022-5185
    Topics: Theology and Religious Studies
    Notes: AUTHORS AND BOOKS REVIEWED OR NOTICED
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1365-2036
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Background: Rectal foam enemas provide for drug delivery to the distal colon for treatment of left sided ulcerative colitis. However, currently available formulations contain chlorofluorocarbons which are due to be phased out in the near future. The objective of this study was therefore to determine the degree of dispersion of a newly developed nonchlorofluorocarbon rectal foam preparation in ulcerative colitis patients. Methods: This was an open label non-controlled study of a single administration of a mesalazine foam enema (two actuations containing 2 g of mesalazine in approximately 120 mL foam) in 10 patients with quiescent ulcerative colitis. Spreading of the 99mTc-labelled foam enema was assessed over a 4-h period by the non-invasive technique of gamma scintigraphy. Results: All patients retained the enema for the full 4-h imaging period. In nine out of the 10 patients, the enema was observed to spread as far as the descending colon and on average 23% of the dose was present in the descending colon at 4 h post-dose. Conclusions: The extent of spreading observed in the study supports the use of the formulation in the treatment of left sided ulcerative colitis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Pacing and clinical electrophysiology 21 (1998), S. 0 
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Numerous types of interactions between pacemakers and implantable cardioverter defibrillators (ICDs) have been described. Pacemaker outputs preventing appropriate detection of ventricular tachycardia or ventricular fibrillation by the ICD is one of the more serious. Asynchronous pacemaker activity during ventricular arrhythmias maybe caused by either nonsensing of the arrhythmia or by noise reversion, which is an algorithm that causes the pacemaker to switch to asynchronous pacing when repetitive sensing at a high rate occurs. We analyzed the mechanisms underlying asynchronous pacemaker activity in ventricular arrhythmias using pacemaker telemetry during the arrhythmia. Thirty-nine induced arrhythmias from 26 different procedures in 19 patients with both pacemakers and ICDs were analyzed. Of the 39 arrhythmias, asynchronous pacemaker activity occurred in 16. The underlying mechanism was nonsensing in 4 episodes and noise reversion in 12 episodes. Clinically significant interference with detection arose on three occasions. Conditions favoring the occurrence of noise reversion include specific pacemaker models, arrhythmia cycle lengths in the range causing noise reversion of the individual pacemaker model, long noise sampling periods, and VVI pacing mode. Noise reversion can be diagnosed by telemetering the pacemaker marker channel during ventricular arrhvthmias as a part of routine pacemaker-ICD interaction evaluation. It can be prevented or minimized by programming short ventricular refractory periods or using pacemakers with shoii retriggerable refractory periods.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Most patients with implantable defibrillators have diminished cardiac function. Progressive heart failure might impair defibrillation efficacy, leading to interpreted device, failure. This study sought to determine the effect of ventricular dysfunction on defibrillation energy using a biphasic endocardial system. Eleven dogs were ventricularly paced at 225 pulses/min for 2 weeks to induce ventricular dysfunction, and five control dogs remained unpaced. Dose response defibrillation probability curves were generated for each animal at baseline, after 2 weeks (at which time the pacemakers were turned off in the paced group), and then 1 week later. The defibrillation thresholds, ED20, ED50, and ED80 (the 20%, 50%, and 80% effective defibrillation energies, respectively) were determined for each dog at each study. In the paced dogs, the mean ejection fraction fell from 55% to 25% after pacing (P 〈 0.0001), and rose to 46% after its discontinuation (P = 0.0002). The defibrillation threshold, ED20, ED50, and ED80 remained unchanged in both the control and paced groups for all three studies, even after adjustment for dog weight or left ventricular mass. Rapid pacing produced no change in left ventricular mass. It induced ventricular cavity dilatation and wall thinning, which had opposing effects on defibrillation energy requirements, resulting in no net change of the ED50 in heart failure. In conclusion, the defibrillation efficacy of a biphasic transvenous system is not changed by the development of heart failure using the rapid paced canine model.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of cardiovascular electrophysiology 7 (1996), S. 0 
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Effects of Slow Pathway Ablation. Introduction: This study investigated whether fast pathway conduction properties are altered by slow pathway ablation in patients with AV nodal reentrant tacbycardia.Methods and Results: Forty consecutive patients who underwent successful ablation of the slow pathway were prospective subjects for the study. Isoproterenol was used to enhance conduction and to differentiate interactive mechanisms. Potential electrotonic interactions were assessed by comparing patients with and those without residual dual AV node pbysiology after slow pathway ablation. Paired and unpaired t-tests were used when appropriate. P 〈 0.05 was considered statistically significant. In the entire study population, heart rates were not significantly different before and after slow pathway ablation (RR = 770 ± 114 msec before and 745 ± 99 msec after, P = 0.07). Anterograde fast pathway conduction properties were unchanged after slow pathway ablation (effective refractory period, 348 ± 84 msec before and 336 ± 86 msec after, P = 0.13; shortest 1:1 conduction, 410 ± 93 msec before and 400 ± 82 msec after, P = 0.39). Retrograde fast pathway characteristics also were similar before and after ablation. Neither anterograde nor retrograde last pathway conduction properties during isoproterenol infusion were changed by slow pathway ablation. When the study population was further divided into patients with (n= 13) or without (n = 27) residual dual AV node pbysiology, no significant change was detected in fast pathway function in either group after slow patbway ablation.Conclusions: Fast pathway conduction characteristics were not affected by slow pathway ablation. In patients with AV nodal reentrant tachycardia, observations suggest that fast and slow pathways are functionally distinct.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of cardiovascular electrophysiology 6 (1995), S. 0 
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Pacer-Cardioverter-Defibrillator. This article reviews the function of the pacer-cardioverter-defibrillator (PCD). Detection of ventricular arrhythmias occurs in two programmable zones, with onset and stability modifiers available to diminish overdetection of sinus tachycardia and atrial fibrillation, respectively. The sensing circuitry utilizes an auto-adjusting sensitivity with exponential decay to allow detection of low-amplitude ventricular fibrillation electrograms without T wave oversensing. Treatment can be accomplished by tiered therapy with two types of antitachycardia pacing, cardioversion and defibrillation. Cardioversion and defibrillation shocks are programmable between single pathway when two leads are used and simultaneous or sequential shock delivery when a three-lead system is used. A telemetered marker channel and electrogram aid in assessing device function during implantation and follow-up. Previously published literature is cited to expand on various aspects of PCD function and programming.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...