Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • 1995-1999  (6)
  • 1965-1969
  • 1945-1949
  • Engineering  (4)
  • Fenoterol  (2)
  • 1
    ISSN: 1432-1041
    Schlagwort(e): Hypokalaemia ; Fenoterol ; Salbutamol ; exercise
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie , Medizin
    Notizen: Abstract Objective: The effect of β2-adrenoceptor agonist-induced hypokalaemia on cardiac arrhythmias might be exacerbated during exercise, especially in patients with more compromised airway function. Methods: To evaluate the effect of β2-adrenoceptor agonists on plasma potassium and cardiopulmonary function during exercise, two identical submaximal treadmill exercise tests were performed, at least 48 h apart, by 13 patients with moderate to severe COPD (11 men and 2 women, mean age 66 y, mean FEV1/FVC ratio 48.9 (2.8)%) 30 min after they had received nebulised fenoterol or salbutamol (2 mg). The experiment was done as a randomised, double-blind, crossover trial after an initial baseline study with vehicle (0.45% saline). Plasma potassium concentration, spirometry and the degree of breathlessness (Borg scale) were measured before treatment and immediately after exercise; oxygen saturation, QTc interval and cardiac rhythm were monitored continuously before, during and for 30 min after exercise. Results: After the saline control, exercise caused an increase in Borg rating (of 4.9), a premature ventricular contractions (VPC) (2.8 beats/min), and a fall in oxygen saturation (-6.7%), but no significant change in plasma potassium (+0.04 mEq·dl−1), FEV1 or QTc interval. Inhalation of fenoterol and salbutamol did not affect QTc interval, Borg scale or VPC frequency at rest, but significantly increased the duration of exercise undertaken to reach the submaximal levels (786 s, versus 783 s) compared to the vehicle control. Following exercise, plasma potassium fell after fenoterol by 0.2 mEq·dl−1 and it increased after salbutamol by 0.1 mEq·dl−1 compared to baseline levels. Plasma potassium after exercise was significantly lower after fenoterol (3.2 mEq·dl−1) compared to the saline control (3.7 mEq · dl−1) and salbutamol (3.6 mEq · dl−1). Neither fenoterol nor salbutamol had any significant effect on the change in FEV1, oxygen saturation, Borg scale, frequency of VPCs or QTc interval during or after exercise compared to the saline control. Conclusion: When compared to salbutamol 2 mg, fenoterol 2 mg caused more marked hypokalaemia but no significant difference in cardiopulmonary response in patients with COPD during exercise.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1432-1041
    Schlagwort(e): Key words Hypokalaemia ; Fenoterol ; Salbutamol; exercise
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie , Medizin
    Notizen: Abstract Objective: The effect of β2-adrenoceptor agonist-induced hypokalaemia on cardiac arrhythmias might be exacerbated during exercise, especially in patients with more compromised airway function. Methods: To evaluate the effect of β2-adrenoceptor agonists on plasma potassium and cardiopulmonary function during exercise, two identical submaximal treadmill exercise tests were performed, at least 48 h apart, by 13 patients with moderate to severe COPD (11 men and 2 women, mean age 66 y, mean FEV1/FVC ratio 48.9 (2.8)%) 30 min after they had received nebulised fenoterol or salbutamol (2 mg). The experiment was done as a randomised, double-blind, crossover trial after an initial baseline study with vehicle (0.45% saline). Plasma potassium concentration, spirometry and the degree of breathlessness (Borg scale) were measured before treatment and immediately after exercise; oxygen saturation, QTc interval and cardiac rhythm were monitored continuously before, during and for 30 min after exercise. Results: After the saline control, exercise caused an increase in Borg rating (of 4.9), a premature ventricular contractions (VPC) (2.8 beats/min), and a fall in oxygen saturation (−6.7%), but no significant change in plasma potassium (+ 0.04 mEq⋅dl−1), FEV1 or QTc interval. Inhalation of fenoterol and salbutamol did not affect QTc interval, Borg scale or VPC frequency at rest, but significantly increased the duration of exercise undertaken to reach the submaximal levels (786 s, versus 783 s) compared to the vehicle control. Following exercise, plasma potassium fell after fenoterol by 0.2 mEq⋅dl−1 and it increased after salbutamol by 0.1 mEq⋅dl−1 compared to baseline levels. Plasma potassium after exercise was significantly lower after fenoterol (3.2 mEq⋅dl−1) compared to the saline control (3.7 mEq⋅dl−1) and salbutamol (3.6 mEq⋅dl−1). Neither fenoterol nor salbutamol had any significant effect on the change in FEV1, oxygen saturation, Borg scale, frequency of VPCs or QTc interval during or after exercise compared to the saline control. Conclusion: When compared to salbutamol 2 mg, fenoterol 2 mg caused more marked hypokalaemia but no significant difference in cardiopulmonary response in patients with COPD during exercise.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Chichester : Wiley-Blackwell
    Communications in Numerical Methods in Engineering 13 (1997), S. 495-510 
    ISSN: 1069-8299
    Schlagwort(e): classical deformation ; shear deformation ; axisymmetric circular plates ; unified finite elements ; Engineering ; Numerical Methods and Modeling
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Mathematik , Technik allgemein
    Notizen: In this paper a unified finite element model that contains the Euler-Bernoulli, Timoshenko and simplified Reddy third-order beam theories as special cases is presented. The element has only four degrees of freedom, namely deflection and rotation at each of its two nodes. Depending on the choice of the element type, the general stiffness matrix can be specialized to any of the three theories by merely assigning proper values to parameters introduced in the development. The element does not experience shear locking, and gives exact generalized nodal displacements for Euler-Bernoulli and Timoshenko beam theories when the beam is homogeneous and has constant geometric properties. While the Timoshenko beam theory requires a shear correction factor, the third-order beam theory does not require specification of a shear correction factor. An extension of the work to axisymmetric bending of circular plates is also presented. A stiffness matrix based on the exact analytical form of the solution of the first-order theory of circular plates is derived. © 1997 John Wiley & Sons, Ltd.
    Zusätzliches Material: 1 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 39 (1996), S. 951-985 
    ISSN: 0029-5981
    Schlagwort(e): time-domainBEM ; 2-D convoluted kernel ; transient wave ; quadratic temporal variation ; elastodynamics ; Engineering ; Engineering General
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Mathematik , Technik allgemein
    Notizen: A quadratic time-domain Boundary Element Method (BEM) for two-dimensional (2-D) elastodynamic transient wave analysis is presented. Emphasis is focused on developing time-domain fundamental convoluted kernels and methodology for quadratic temporal solution procedure which are never presented before. In the presented BEM method, the displacement temporal variation is assumed to be quadratic, the traction temporal variation is assumed to be linear (called QL method, a two-time-step piecewise continuity method), and the spatial variations are assumed to be quadratic variation. The QL method is compared with the LC method and the QC method by solving several example problems. Numerical study reveals that the QC and QL methods are more accurate and stable than the LC method, and the QL method is much better than the QC method for transient problems.
    Zusätzliches Material: 22 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    New York, NY [u.a.] : Wiley-Blackwell
    International Journal for Numerical and Analytical Methods in Geomechanics 22 (1998), S. 425-447 
    ISSN: 0363-9061
    Schlagwort(e): closed-form solution ; transversely isotropic half-space ; Fourier transform ; Hankel transform ; rock anisotropy ; Engineering ; Civil and Mechanical Engineering
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Architektur, Bauingenieurwesen, Vermessung , Geologie und Paläontologie
    Notizen: We rederive and present the complete closed-form solutions of the displacements and stresses subjected to a point load in a transversely isotropic elastic half-space. The half-space is bounded by a horizontal surface, and the plane of transverse isotropy of the medium is parallel to the horizontal surface. The solutions are obtained by superposing the solutions of two infinite spaces, one acting a point load in its interior and the other being free loading. The Fourier and Hankel transforms in a cylindrical co-ordinate system are employed for deriving the analytical solutions. These solutions are identical with the Mindlin and Boussinesq solutions if the half-space is homogeneous, linear elastic, and isotropic. Also, the Lekhnitskii solution for a transversely isotropic half-space subjected to a vertical point load on its horizontal surface is one of these solutions. Furthermore, an illustrative example is given to show the effect of degree of rock anisotropy on the vertical surface displacement and vertical stress that are induced by a single vertical concentrated force acting on the surface. The results indicate that the displacement and stress accounted for rock anisotropy are quite different for the displacement and stress calculated from isotropic solutions. © 1998 John Wiley & Sons, Ltd.
    Zusätzliches Material: 5 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    New York, NY [u.a.] : Wiley-Blackwell
    International Journal for Numerical and Analytical Methods in Geomechanics 22 (1998), S. 495-508 
    ISSN: 0363-9061
    Schlagwort(e): consolidation ; cohesive soil ; clay ; axial strain ; true triaxial ; finite difference method ; Engineering ; Civil and Mechanical Engineering
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Architektur, Bauingenieurwesen, Vermessung , Geologie und Paläontologie
    Notizen: This paper presents a simplified approach for the analysis of axial strain induced by three-dimensional consolidation of cohesive soils. The axial strain is divided into a constant volume component and a consolidation component. A relevant undrained stress-strain relationship is required to determine the constant volume component. A theoretical formulation is developed for the evaluation of the consolidation component. Predictions of the axial strain accompanying true triaxial laboratory tests for a variety of stress patterns correlate sufficiently well with the measured data. The proposed method is potentially applicable in conjunction with a finite difference scheme to analyze the time-dependent response of pile groups subjected to static vertical loading. © 1998 John Wiley & Sons, Ltd.
    Zusätzliches Material: 10 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...