Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 0935-6304
    Keywords: Chlorobiphenyl congeners ; Aroclors ; DB-XLB phase ; HP-5/HT-5 serial coupled phases ; GC-ECD ; GC-MS-SIM ; GC-Ion Trap MS ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Three HRGC systems (1: 30m DB-XLB capillary with MS-SIM detection; 2: 60m DB-XLB capillary with full-scan, ion-trap MS detection; and 3: Parallel dual-column DB-17 and series-coupled HP5/HT5 with ECD detection) were used to completely characterize multiple lots of 8 different-numbered Aroclor mixtures by quantitative calibration against 9 solutions containing primary standards of all 209 PCB congeners. Despite lower absolute sensitivity and more Aroclor congener coelutions than the dual-column ECD system, the MS systems enabled measurement of more congeners per Aroclor since their greater linear response range did not require dilution of samples and standards. Pairs of different lots of Aroclors 1248 and 1254 displayed markedly different proportions of congeners, and the 1254 pair displayed strong differences in the extent of ortho-chlorine substitution. The tables of congener weight percent distributions among Aroclors are more comprehensive and quantitatively precise than those of prior publications. However, the limitations of single-level calibration precluded measurement of all congeners to the ±10% accuracy desirable for establishing these Aroclors as secondary standards for comprehensive, quantitative congener-specific PCB analysis.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 533-540 
    ISSN: 0935-6304
    Keywords: Chlorobiphenyl congeners ; Aroclor 1254 ; DB-XLB phase ; GC-MS-SIM ; PCB 126 ; toxic equivalency ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---Complete PCB congener distributions in a panel of Aroclor mixtures were previously obtained by combining data from several HRGC systems. In that study quantitation of minor components may have been unreliable due to single level calibration against high levels of individual congener standards. Two lots of Aroclor 1254 had markedly different congener distributions. In this study, the design and performance of a congener-specific PCB analysis method employing GC-MS-SIM detection of congeners separated on a DB-XLB capillary column are discussed. Quantitation is carried out against a 6-level inclusive standard curve of a mixture of 144 congeners found in Aroclors. A separate procedure to measure trace levels of PCB 126 in Aroclors using the same system, combined with levels initially acquired for other congeners, facilitates estimation of TEQ values (Toxic Equivalencies of the PCB mixtures to 2,3,7,8-TCDD). PCB congener profiles of 15 Aroclor 1254 mixtures are presented. These profiles show that the less common, high TEQ variety of Aroclor 1254 was manufactured by an atypical, two-stage chlorination process that was apparently used during the final 1% of Aroclor 1254 production (ca. 1974-1976).
    Additional Material: 5 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...