Library

Your search history is empty.
feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (1)
  • 1905-1909
  • Key words: Aorta, transluminal angioplasty—Arteries—Stents and prostheses  (1)
  • 1
    ISSN: 1432-086X
    Keywords: Key words: Aorta, transluminal angioplasty—Arteries—Stents and prostheses
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Purpose: To assess the technical success, initial clinical outcome, and intermediate follow-up of the Memotherm nitinol self-expanding stent in aortic bifurcation reconstruction. Methods: Thirty-three patients (13 male, 20 female), mean age 64 years, were treated, who had symptoms classified by the Surgical Vascular Society/International Society of Cardiovascular Surgery (SVS/ICVS) classification as grade 2 in 11 (33%), grade 3 in 19 (58%) and grade 4 in 3 (9%) patients. Lesions were classified according to severity and type. Indications for placement of a Memotherm nitinol self-expanding stent were failed angioplasty in 14 (42%), chronic occlusions in 12 (37%), and complex stenoses in seven (21%) patients. Results: Sixty-seven stents were technically successfully placed in 66 aorto-iliac segments in 33 patients, with one major complication. Initial clinical outcome was improvement in 25 (81%), no change in four (13%), and a worsening in two (6%) patients by Rutherford criteria. Mean early ankle/brachial pressure index (ABI) gain was 0.27 for occlusions and 0.05 for stenoses. Clinical follow-up was obtained in all patients, with retrospective angiographic follow-up in 28 (85%) at a mean of 16 months (range 12–26 months). The decrease in ABI and the decrease in angiographic luminal diameter at follow-up was determined as the “late loss.” The mean ABI late losses were −0.06, 0.00, and 0.09, and the mean angiographic late losses were 6.7%, 10% and 14% for occlusions, stenoses, and normal segments respectively. Primary clinical patency was 96%, primary angiographic patency was 89%, and secondary angiographic patency was 93%. Conclusion: The high technical success of stent placement, the low complication rates for aortic bifurcation reconstruction using the Memotherm self-expanding stent, and high clinical and angiographic patency maintained at intermediate follow-up support their use in aortic bifurcation reconstruction.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...