Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (2)
  • Anxiety  (1)
  • Dual-radionuclide single-photon emission tomography  (1)
  • (Bovine liver)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Psychopharmacology 123 (1996), S. 182-186 
    ISSN: 1432-2072
    Keywords: Anxiety ; Conditioned fear stress ; Freezing behavior ; Serotonin reuptake inhibitors ; Citalopram ; Fluvoxamine ; Milnacipran
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Conditioned fear stress (CFS)-induced freezing behavior has been proposed as an animal model of anxiety. In the present study, freezing was used to determine the anxiolytic activity of selective serotonin reuptake inhibitors (SSRIs), which are reported to be clinically effective in anxiety disorders. The duration of freezing behavior was reduced by acute treatment with the SSRIs citalopram (1–10 mg/kg) and fluvoxamine (3–30 mg/kg). Acute treatment with the serotonin (5-HT)/noradrenaline (NA) mixed reuptake inhibitor milnacipran (3–30 mg/kg) also attenuated CFS-induced freezing, while acute treatment with the NA reuptake inhibitors maprotiline and ORG4428, and the dopamine (DA) reuptake inhibitor GBR12909 failed to alter CFS-induced freezing. These results indicate that facilitation of 5-HT availability in the brain produced by 5-HT reuptake inhibition reduces CFS-induced freezing behavior. CFS may be a useful model for detecting the anxiolytic potential of 5-HT reuptake inhibitors.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1619-7089
    Keywords: Key words: Pulmonary ventilation/perfusion ratio ; Dual-radionuclide single-photon emission tomography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. To date, there has been neither a good method to clarify the three-dimensional distribution of pulmonary ventilation/perfusion (V.A/Q.) ratios, nor a convenient way to assess V.A/Q. inequality. The purpose of this study was to develop a functional image of pulmonary V.A/Q. ratios based on data acquired with simultaneous dual-radionuclide single-photon emission tomography (SPET) and to assess V.A/Q. unevenness through the V.A/Q. histogram in patients with various pulmonary diseases. Dual-radionuclide SPET was performed with technetium-99m macroaggregated albumin (MAA) and krypton-81m, with the patient in the supine position. After correction for linear cross-talk, the total acquisition counts of both radionuclides were equalized. The V.A/Q. ratio, which was calculated in each pixel by dividing the 81mKr count by the 99mTc-MAA count, was expressed as a V.A/Q. image. A histogram of the pixel number plotted against the V.A/Q. ratios was then produced and its centre of weight (CW) and standard deviation (SD) determined. Ten healthy volunteers and 46 patients [seven with pulmonary vascular disease (PVD), nine with pulmonary emphysema (PE), 18 with bronchogenic carcinoma and 12 with miscellaneous diseases] participated in this study. In normal volunteers, V.A/Q. ratios were generally even, but were slightly lower in dorsal regions. Patients with PVD had lobar and/or segmental areas with a high V.A/Q. ratio. Low V.A/Q. areas extended widely in patients with PE. Bronchogenic carcinoma exceeding 3 cm in diameter was detected as a very low V.A/Q. area. The SD of V.A/Q. ratios had a significant positive correlation both with A-aDO2 (r=0.64, P〈0.001) and with cigarette smoking history (r=0.72, P〈0.001). It is concluded that the V.A/Q. ratio image produced with simultaneous dual-radionuclide SPET using 99mTc-MAA and 81mKr is a unique and simple method for demonstrating the three-dimensional distribution of V.A/Q. ratios. The unevenness of V.A/Q. distribution can be assessed through the SD of the V.A/Q. histogram.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...