Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (3)
  • 21.10.Ft  (2)
  • Binocular depth inversion  (1)
  • Nitrite reductase
  • 1
    ISSN: 1434-601X
    Keywords: 21.10.Ft ; 25.70.Np ; 27.40.+Z
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract At the projectile-fragment separator FRS of GSI, relativistic secondary beams of about 520 MeV/nucleon were produced by fragmentation of a primary beam of58Ni at 650 MeV/nucleon in a beryllium target. By means of aΔE—Bρ—TOF measurement, the fragments have been identified and their charge-changing probabilities in targets of CH2, C, Al, and Pb have been determined. We describe the results for the total charge-changing cross sections in this first paper, whereas a second article deals with the partial charge-changing cross sections. At the drip line, the measured charge-changing cross sections exhaust close to 100% of the total interaction cross sections as calculated with semiempirical models. The measurements at the proton drip line with low-Z targets indicate that only a very small increase of the cross sections may be observed, whereas the measurements with a lead target show that no significant increase of the total charge-changing cross sections is present which would be a hint for low-lying dipole strength. Our experimental data are compared to Glauber-type calculations.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1434-601X
    Keywords: 21.10.Ft ; 25.70.Np ; 27.40.+z
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract At the projectile-fragment separator FRS of GSI, relativistic secondary beams of about 520 MeV/nucleon were produced by fragmentation of a primary beam of58Ni at 650 MeV/nucleon in a beryllium target. By means of aΔE—Bρ—TOF measurement, the fragments were identified and their charge-changing probabilities in targets of (CH2) n , C, Al, and Pb placed at the exit of the FRS were determined. Whereas a first article dealt with the total charge-changing cross sections, we describe in this second article the element distributions of these secondary fragments, which are found to depend strongly on the isospin of the secondary projectile as well as on the target material. In the case of the lead target, the influence of the electromagnetic dissociation is clearly visible in the one-proton and two-proton removal channels. The preference for the formation of even-Z fragments is much more pronounced for exotic secondary projectiles than for projectiles close to stability. Calculations with a geometrical abrasion-ablation model allow to understand the global features of the experimental data. However, far from stability, the discrepancies between calculations and experimental data increase.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    European archives of psychiatry and clinical neuroscience 246 (1996), S. 256-260 
    ISSN: 1433-8491
    Keywords: Binocular depth inversion ; Schizophrenia ; Alcohol withdrawal ; Sleep deprivation ; Systems theory
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Binocular depth inversion represents an illusion of visual perception. Such an inversion does not occur in all cases, especially when objects with a higher degree of familiarity (e.g. photographs of faces) are displayed. Cognitive factors are assumed to override the binocular disparity cues of stereopsis. We tested the hypothesis that during psychotic and similar states the human CNS is unable to correct the implausible perceptual hypothesis. Measurements of binocular depth inversion in perception of 3D objects were performed in schizophrenic patients (n=13), in patients with alcohol withdrawal (n=10), in sleep-deprived medical staff (n=10) and in healthy volunteers (n=41). The binocular depth inversion scores were highly elevated in the patient group and in the sleep-deprivated medical staff in comparison with healthy volunteers. The data demonstrate that impairment of binocular depth inversion reflects a common final pathway, characterized by an impairment of adaptive systems regulating perception.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...