Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (2)
  • 42.65.Re  (1)
  • Polymer and Materials Science
  • glucagon
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 63 (1996), S. 255-264 
    ISSN: 1432-0649
    Keywords: 07.60.Ly ; 42.65.Re ; 78.47. + p
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract A femtosecond frequency-domain interferometer is applied to metal-free and vanadyl phthalocyanine (H2Pc and VOPc) thin films to measure time-resolved difference phase and transmission spectra simultaneously. For both samples, the phase-change dynamics is different from the transmission-change dynamics at 620 nm, reflecting that the phthalocyanines (Pc) cannot be modeled with a two-level system but by a multi-level or inhomogeneously broadened system, in which each level pair exhibits different relaxation dynamics. Because of this dynamical difference, a phase-change measurement is required to correct distortion of the transient spectra due to induced phase modulation of probe pulses. Near zero time delay, the phase and transmission changes show different growth behavior. This behavior is explained by antisymmetric amplitude and phase gratings which are produced by coherent coupling between frequency-chirped pump and probe pulses.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 37 (1997), S. 100-107 
    ISSN: 0021-9304
    Keywords: Diopside ; biocompatibility ; osteogenic cell (MC3T3-E1) ; biomechanical strength ; apatite wollastonite-containing glass-ceramic (AWGC) ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Diopside was prepared by sintering a powder compact composed of CaMgSi2O6 at 1573K for 2 h. In order to clarify the biocompatibility of Diopside, the cytotoxicity of Diopside against the osteogenic cell line MC3T3-E1 and the bone-Diopside interface strength were examined. On both the 14th and 21st days of incubation of MC3T3-E1 cells with Diopside, ALP activities were not significantly lower than those of the CTRL. TEM photographs of MC3T3-E1 on Diopside after 14 days of incubation showed active secretion of crystals from osteoblast-like cells. Scanning electron microscopic analysis showed that the cells on Diopside formed multiple cell layers similar to those on the CTRL both 14 and 21 days after incubation. These results showed that Diopside had no cytotoxic effect on MC3T3-E1. The pulling test showed that failure loads of Diopside were significantly lower than those of AWGC. Histologically, there was no fibrous tissue or foreign body reaction at the bone interface. SEM-EPMA showed that Diopside had attached to the bone via a calcium-phosphorus layer. SEM back-scattered electron imaging showed that the Diopside plate had degraded to a porous state 12 weeks after implantation. These findings indicate that Diopside is a biodegradable ceramic. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res, 37, 100-107, 1997.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...