Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (2)
  • Column liquid chromatography  (1)
  • Jet-injection  (1)
  • Bioavailability
  • 1
    ISSN: 1432-1041
    Keywords: Growth hormone ; Jet-injection ; pharmacokinetics ; pharmacodynamics ; Somatomedin C ; free fatty acids
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Abstract The pharmacokinetics and pharmacodynamics of recombinant human growth hormone (rhGH) were studied after a single subcutaneous dose given by jet-injection, and have been compared with the results obtained after conventional needle-injection. Twelve healthy male volunteers completed an open label, randomised, two-way crossover study, with a 7-day washout period between the two single sc doses. Pharmacokinetic parameters were derived from rhGH concentrations in blood samples collected regularly over 24 h after dosing on Day 1 of each period. To investigate the pharmacodynamics, additional samples were taken for the analysis of somatomedin C (IGF-I) and free fatty acids (FFA). A higher and earlier Cmax was found after jet-injection (ratio (%) jet-injected/needle-injected 124; 90%-confidence interval 108 – 142). The AUC0−∞ for rhGH were similar (ratio (%) jet-injected/needle-injected 98; 90%-confidence interval 93 – 103). Both treatments were associated with a significant and similar rise in IGF-I. Both administrations of rhGH were associated with identical rhythmical changes in FFA. The study indicates that jet-injected and needle-injected rhGH are bioequivalent with respect to the amount absorbed. The criterion for bioequivalence is not met for the rate of absorption. It is unlikely that the latter finding will influence the pharmacodynamics of rhGH, since bioequipotency was established for the effect on IGF-I generation. Jet-injection was safe in use and was generally well tolerated.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Metformin analysis ; Stationary phase variability ; Validation of methods
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Two assay methods for the antidiabetic metformin, one developed and validated in 1990 and one developed and validated in 1996, are compared. The first method, using an octadecyl phase and an ion pairing agent in the eluent, could not be reproduced some five years later, but another method, using a phenyl phase and no ion pairing agent, could be successfully applied. This paper shows that the retention mechanism of the positively charged analyte is not due to ion-pair formation, as originally assumed, but to interaction with free silanol groups in the LC phase. It is suggested that the number of free silanol groups in octadecyl phases was strongly reduced between 1990 and 1996, whereas for phenyl phases this was not the case. For the second method, validation results on linearity, specificity, accuracy, precision, recovery and stability as well as application of the method to samples from a clinical trial are shown. The validated calibration range is from 20.0 to 2000 ng.mL−1, with accuracy (bias) and precision (coefficient of variation) being below 15% at all levels. Using automated solid-phase extraction for sample preparation, a sample throughput of typically 100 per day can be achieved.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...