Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (5)
  • Biochemistry and Biotechnology  (4)
  • Electrochemical detection  (3)
  • General Chemistry
  • 1
    ISSN: 0006-3592
    Keywords: RGD ; FMDV ; internalization ; integrins ; cell binding ; β-galactosidase ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: The G-H loop of foot-and-mouth disease virus is a disordered protrusion of the VP1 protein exposed on the virion surface. This short stretch includes an arginine-glycine-aspartic acid tripeptide, a recognized integrin-binding motif, which is responsible for cell attachment and infection. Eight copies of a peptide reproducing the amino acid sequence of this FMDV ligand have been displayed in solvent-exposed regions on an enzymatically active recombinant β-galactosidase. This viral peptide segment enables the chimeric enzyme to bind mammalian cell lines with different efficiencies, probably depending on the number of suitable cell receptors present on each of them. Moreover, it also promotes the internalization of the attached enzyme, which is transiently active inside the cells. These results suggest further exploration of the potential use of short adhesion peptides of viral origin as cell attachment tags to direct the targeted delivery of both genes and enzymes, instead of whole, infectious viruses. © 1998 John Wiley & Sons, Inc. Biotechnol Bioeng 59:294-301, 1998.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0947-6539
    Keywords: cyclovoltammetry ; electronic effects ; photoelectron spectroscopy ; pyrazole ligands ; Mössbauer spectroscopy ; Chemistry ; General Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The electronic effect of substituting CH with N in poly(pyrazolyl)-borato ligands and their transition-metal complexes is shown to be a decrease in energy of the filled metal and ligand orbitals. This conclusion is based on the cyclovoltammograms and photoelectron spectra of bis(hydrotris(azolyl)borato)-iron(II) and -cobalt(II) complexes (azolyl = pyrazolyl and 1,2,4-triazolyl) and on MO calculations. 57Fe Mössbauer spectra of bis(hydrotris(1,2,4-triazolyl)-borato)iron(II) show that there is a fine-tuning of the HOMO-LUMO gap by a shift in transition temperature for the spin equilibrium. 15N NMR spectroscopy supports the assignment of a higher negative charge to the exodentate N-4 nitrogen than to the endodentate N-2 or N-3 positions in the poly(azolyl)borato anions, where azolyl is 1,2,4-triazolyl or tetrazolyl. The electron withdrawing effect of the additional nitrogen atoms and the in-corporation of water of crystallization by O-H ⃛ N bonding both assist in the formation of (azolyl)C-H ⃛ O bonds.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Electrophoresis 18 (1997), S. 2267-2278 
    ISSN: 0173-0835
    Keywords: Capillary electrophoresis ; Electrochemical detection ; Decoupling ; Capillary-electrode alignment ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Recent advances in the design and application of electrochemical detection (EC) systems in capillary electrophoresis (CE) are reviewed, with the objective of providing the non-electrochemist with a state-of-the-art picture of CEEC instrumentation and an overview of the primary analytes and samples for which the technique is best suited. In particular, instrument innovations designed to aid in decoupling the CE and EC systems electrically and in aligning them physically are described in detail. In addition, CEEC applications are summarized for four specific analyte groups: catecholamines, thiols and disulfides, amino acids, and carbohydrates. On this basis, it is clear that EC techniques have reached a stage where they are already having a significant impact on CE usage in selected areas of analysis. Continued developments with respect to new electrode materials and electrode configurations promise to broaden this impact further.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Electrophoresis 19 (1998), S. 2226-2232 
    ISSN: 0173-0835
    Keywords: Electrochemical detection ; Capillary electrophoresis ; Dual-parallel electrodes ; On-capillary electrodes ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: A new approach for dual electrode electrochemical detection in capillary electrophoresis (CEEC) is described. In this approach, two identical capillaries, each containing an on-capillary electrode incorporated permanently onto its tip, were paired together for simultaneous sample injection and detection. This procedure permitted dual-parallel detection to be performed without the need for painstaking alignment of the electrodes with respect to one another and to the capillary outlet as is required for the off-capillary microelectrode systems usually employed in CEEC. As a result, independent detection at two electrodes held at different potentials or at two electrodes of different composition or structure could be performed simply and with wide flexibility. Fabrication of on-capillary electrodes was carried out by sputter-coating the exit end of the capillaries with a thin layer of Au or Pt. Dual electrode system performance was demonstrated by separation and analysis of phenol and catechol samples. In addition, the detection system was coupled with glucose oxidase for the selective detection of glucose.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 0173-0835
    Keywords: Capillary electrophoresis ; Polysaccharides ; Electrochemical detection ; Cu electrode ; Carbohydrates ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Complex polysaccharide mixtures were analyzed directly without derivatization by capillary zone electrophoresis in strongly alkaline solutions and electrochemical detection at a Cu electrode. The positively charged surfactant cetyltrimethylammonium bromide was included in the electrophoresis medium in order to reverse the electroosmotic flow and permit elution to be in order of increasing polysaccharide size. Carbohydrate samples analyzed by this approach included linear maltoses, enzymatically hydrolyzed starch, and commercially available dextrans of up to an average molecular weight of 18 300. Detection by constant-potential oxidation at a Cu electrode was very sensitive, with detection limits for individual carbohydrates generally below the femtomole level.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...