Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (1)
  • Budesonide  (1)
  • 1
    ISSN: 1432-1041
    Keywords: Key words Asthma ; Fluticasone propionate ; Budesonide
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Abstract Objective: The aim of this study was to evaluate the steady-state effects of once-daily inhaled fluticasone propionate (FP) and budesonide (BUD) on adrenocortical activity in asthmatic patients. Methods: Ten asthmatic patients with a mean age of 31.2 years, a mean forced expiratory volume in 1 s (FEV1) of 91% predicted and a forced mid-expiratory flow (FEF25–75) of 62.3% predicted were studied in a single-blind randomised crossover design comparing placebo (PL), FP (375 μg per day and 750 μg per day) and BUD (400 μg per day and 800 μg per day) all given once daily for 4 days at each dose via a pressurised metered dose inhaler (pMDI) at 0800 hours. After 4 days of treatment, plasma cortisol was measured at 0800 hours (24 h after the last dose) and a 10-h overnight urine collection was taken, 14 h after the last dose (2200–0800 hours) for analysis of cortisol and creatinine excretion. Results: Plasma cortisol levels (nmol · l−1, as geometric mean) at 0800 hours demonstrated a significant difference between the highest doses of FP and BUD (424.1 vs 510.3 nmol · l−1, respectively) but not between the low doses (506.8 vs 514.9 nmol · l−1; PL 532.2 nmol · l−1). For the highest dose FP (750 μg) this equated to 20% suppression of 0800 hours plasma cortisol. Likewise, for overnight urinary cortisol output (nmol · 10 h−1, as geometric mean), there was a significant difference at the high doses of FP and BUD (25.5 vs 38.2 nmol · 10 h−1), but not at the low doses 31.3 vs 34.8 nmol · 10 h−1; PL 32.0 nmol · 10 h−1. For the overnight urinary cortisol/creatinine ratio (nmol · mmol−1, as geometric mean) there was a similar trend; 4.5 vs 6.1 nmol · mmol−1 for high dose and 5.6 vs 6.3 nmol · mmol−1 for low dose; PL 5.9 nmol · mmol−1. Conclusion: Repeated doses of FP 750 μg once daily caused greater adrenal suppression than BUD 800 μg once daily, when comparing effects on plasma cortisol levels at 0800 hours, 24 h after the last dose, as well as effects on overnight urinary cortisol output. Neither FP 375 μg once daily nor BUD 400 μg once daily produced detectable adrenal suppression.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...