Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (2)
  • Electrocatalysis  (1)
  • Voltammetry  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Journal of solid state electrochemistry 2 (1998), S. 247-252 
    ISSN: 1433-0768
    Keywords: Key words Silica ; Voltammetry ; Polyoxometalate ; Diffusion ; Solids
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract Voltammetry of silicotungstic acid (STA), H4SiW12O40, that was encapsulated in silica was performed in the absence of a contacting liquid phase. Two one-electron reductions that are separated by 200 mV were observed, which is the same behavior as in aqueous solution. At scan rates, v, below 10 mV s−1 with a 10 μm dia. carbon fiber indicator electrode, plateaus with limiting currents which are independent of v were observed, which is indicative of spherical diffusion from a field that is much larger than the electrode area. At v 〉 20 V s−1, peaks were observed with currents directly proportional to v ½. For a gel aged for 2 days, an effective diffusion coefficient, D eff, of 3 × 10−7 cm2 s−1 was estimated by voltammetry and chronoamperometry; the concentration of the redox sites thereby determined was about 0.5 M. The D eff values that were obtained in this study were larger than expected for a solid electrolyte, which suggests an important role of residual water. In support of this model, gels that were aged in a humidistat at 33% humidity at room temperature for 2 and 5 days lost 16% and 13%, respectively, of their mass when dried at 120°.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1040-0397
    Keywords: Heparin ; Modified electrodes ; Electrocatalysis ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The electrochemical oxidation of full-size heparin (13-15 kDa) is demonstrated in 1 M H3PO4 at a glassy carbon electrode coated with a ruthenium oxide film. The pathway apparently is analogous to chemical oxidation by periodate. By comparison to currents from inorganic species, it is apparent that only about 2 electrons per mole are involved. Flow injection analysis (FIA) allowed determinations down to 2 μM heparin, but the calibration plot was nonlinear. Low molecular weight heparin (5-6 kDa) was not electroactive with this system. In basic solution at a glassy carbon electrode that is modified with a film of Cu2O, both full-size and low molecular weight heparin are oxidized. The pathways involved oxidative desulfation and attack on saccharide units with evolution of CO2. Linear calibration plots which extended into the sub-μM level were obtained by FIA. The detection limits, which were based on a value of 3 for the ratio of the signal to the standard deviation of replicates, were 9 nM for full-size and 20-30 nM for various low molecular weight heparin samples.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...