Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Journal of cancer research and clinical oncology 123 (1997), S. 219-223 
    ISSN: 1432-1335
    Keywords: Key words Liver neoplasm ; Ultrasound therapy ; Sonography monitoring
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract  This project aimed to determine the adequacy and accuracy of high-intensity focused ultrasound (HIFU) for ablating experimental liver tumour, and to assess imaging methods for monitoring the therapeutic results. The rabbit liver pseudotumour model was established by injection of Freund’s complete adjuvant into the liver; the animals then received HIFU therapy via laparotomy at the focal point of the beam (1.1 MHz, 500 W/cm2, 20 s). The rabbits were sacrificed at scheduled times after treatment and liver tumours were examined histologically. Sequential imaging of the liver tumour was performed before and after HIFU treatment. HIFU accurately destroyed the rabbit liver tumour and induced coagulation necrosis 24 h later. Sonographic imaging studies revealed that characteristic changes occurred. A hyperechoic mass turned to a hypoechoic lesion with no Doppler signal, and a high echogenic rim appeared 24 h after HIFU treatment, correlating well with the pathological changes of a sonoablated lesion. These results verify that HIFU has the power to ablate liver tumour quite adequately and accurately, and that sonography is useful for monitoring sonoablated liver tumour.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Journal of cancer research and clinical oncology 123 (1997), S. 219-223 
    ISSN: 1432-1335
    Keywords: Liver neoplasm ; Ultrasound therapy ; Sonography monitoring
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract This project aimed to determine the adequacy and accuracy of high-intensity focused ultrasound (HIFU) for ablating experimental liver tumour, and to assess imaging methods for monitoring the therapeutic results. The rabbit liver pseudotumour model was established by injection of Freund's complete adjuvant into the liver; the animals then received HIFU therapy via laparotomy at the focal point of the beam (1.1 MHz, 500 W/cm2, 20 s). The rabbits were sacrificed at scheduled times after treatment and liver tumours were examined histologically. Sequential imaging of the liver tumour was performed before and after HIFU treatment. HIFU accurately destroyed the rabbit liver tumour and induced coagulation necrosis 24 h later. Sonographic imaging studies revealed that characteristic changes occurred. A hyperechoic mass turned to a hypoechoic lesion with no Doppler signal, and a high echogenic rim appeared 24 h after HIFU treatment, correlating well with the pathological changes of a sonoablated lesion. These results verify that HIFU has the power to ablate liver tumour quite adequately and accurately, and that sonography is useful for monitoring sonoablated liver tumour.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...