    Springer
    Intensive care medicine 22 (1996), S. 1169-1175 
    ISSN: 1432-1238
    Schlagwort(e): Macrophage inflammatory protein-1 alpha (MIP-1α) kwInterleukin-8 (IL-8) ; Sepsis ; Disseminated intravascular Coagulation (DIC)
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract We studied blood MIP-1α and IL-8 in 38 septic patients and 5 healthy volunteers. Both chemokines were undetectable in the healthy volunteers. In sepsis, serum MIP-1α was detected in 45% of the patients and IL-8 in 84%. The levels of MIP-1α, but not of IL-8, correlated with CRP, IL-6 and TNFα levels. Complication, including various organ failures and mortality, showed no correlation with serum MIP-1α levels. In contrast, we found increased levels of serum IL-8 in septic patients with disseminated intravascular coagulation, central nervous system (CNS) dysfunction or renal failure, and the mortality rate was higher in the IL-8-detectable group than in the IL-8 undetectable group (50% vs 0%,p〈0.05). In conclusion, the production of both MIP-1α and IL-8 was increased and initially detectable levels of circulating IL-8 predicted high mortality in sepsis. Objective To determine the significance of the C-C chemokine MIP-1α and the C-X-C chemokine IL-8 in sepsis. Design Prospective study. Setting Clinical investigation, emergency department and general intensive care unit of university hospital. Patients and participants 38 septic patients and 5 healthy volunteers were studied. Sepsis was diagnosed following the criteria formulated by ACCP/SCCM. Interventions 10–20 ml of blood was drawn from each patient at the time of initial diagnosis of sepsis. Measurements and results MIP-1α and IL-8 were determined by sand-wich ELISA. Both chemokines were undetectable in the healthy volunteers. In sepsis, serum MIP-1α was detected in 45% of the patients and IL-8 was detected in 84%. The levels of MIP-1α, but not of IL-8, correlated with CRP, IL-6 and TNFα levels. Complications, including various organ failures and mortality, showed no correlation with serum MIP-1α levels. In contrast, we found increased levels of serum IL-8 in patients with disseminated intravascular coagulation (DIC) (p〈0.05), central nervous system (CNS) dysfunction (p〈0.05), renal failure (p〈0.01) and the mortality rates were higher in the IL-8 detectable group than in the IL-8 undetectable group (50% vs 0%,p〈0.05). Conclusions The production of MIP-1α and IL-8 was increased in sepsis. Furthermore, an initially detectable level of circulating IL-8, but not MIP-1α, predicted a high mortality in sepsis diagnosed according to the ACCP/SCCM criteria.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    Intensive care medicine 22 (1996), S. 1169-1175 
    ISSN: 1432-1238
    Schlagwort(e): Key words Macrophage inflammatory protein-1alpha (MIP-1α) ; Interleukin-8 (IL-8) ; Sepsis ; Disseminated intravascular Coagulation (DIC)
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Beschreibung / Inhaltsverzeichnis: Structured Abstract   Objective: To determine the significance of the C–C chemokine MIP-1α and the C–X–C chemokine IL-8 in sepsis. Design: Prospective study. Setting: Clinical investigation, emergency department and general intensive care unit of university hospital. Patients and participants: 38 septic patients and 5 healthy volunteers were studied. Sepsis was diagnosed following the criteria formulated by ACCP/SCCM. Interventions: 10–20 ml of blood was drawn from each patient at the time of initial diagnosis of sepsis. Measurements and results: MIP-1α and IL-8 were determined by sandwich ELISA. Both chemokines were undetectable in the healthy volunteers. In sepsis, serum MIP-1α was detected in 45% of the patients and IL-8 was detected in 84%. The levels of MIP-1α, but not of IL-8, correlated with CRP, IL-6 and TNFα levels. Complications, including various organ failures and mortality, showed no correlation with serum MIP-1α levels. In contrast, we found increased levels of serum IL-8 in patients with disseminated intravascular coagulation (DIC) (p〈0.05), central nervous system (CNS) dysfunction (p〈0.05), renal failure (p〈0.01) and the mortality rates were higher in the IL-8 detectable group than in the IL-8 undetectable group (50% vs 0%, p〈0.05). Conclusions: The production of MIP-1α and IL-8 was increased in sepsis. Furthermore, an initially detectable level of circulating IL-8, but not MIP-1α, predicted a high mortality in sepsis diagnosed according to the ACCP/SCCM criteria.
    Notizen: Abstract  We studied blood MIP-1α and IL-8 in 38 septic patients and 5 healthy volunteers. Both chemokines were undetectable in the healthy volunteers. In sepsis, serum MIP-1α was detected in 45% of the patients and IL-8 in 84%. The levels of MIP-1α, but not of IL-8, correlated with CRP, IL-6 and TNFα levels. Complications, including various organ failures and mortality, showed no correlation with serum MIP-1α levels. In contrast, we found increased levels of serum IL-8 in septic patients with disseminated intravascular coagulation, central nervous system (CNS) dysfunction or renal failure, and the mortality rate was higher in the IL-8-detectable group than in the IL-8 undetectable group (50% vs 0%, p〈0.05). In conclusion, the production of both MIP-1α and IL-8 was increased and initially detectable levels of circulating IL-8 predicted high mortality in sepsis.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    ISSN: 1432-1238
    Schlagwort(e): Key words Sarin ; Organophosphate ; Acetylcholinesterase ; Miosis ; Cholinesterase ; Nerve agent
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Objective : To elucidate the effect of sarin vapor on pupil size and erythrocyte acetylcholinesterase activity (AchE). Design: Retrospective observational survey. Setting: Emergency department of an urban teaching hosp
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    ISSN: 1432-1238
    Schlagwort(e): Sarin ; Organophosphate ; Secondary exposure
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Objective To clarify the risk of secondary exposure of medical staff to sarin vapor in the emergency room, and to warn emergency room staffs of the hazard. Design Retrospective observational survery. Setting Emergency department of a university hospital in a metropolitan area of Japan. Participants Fifteen doctors treating victims of a terrorist attack with sarin in the Tokyo subways on the day of the attack. Measurements and results Of the 15 doctors who worked in the emergency room treating the victims, 13 became simultaneously aware of symptoms during the resuscitation of two victims who were exposed to sarin. Among 11 doctors (73%) who complained of dim vision, the pupils were severely miotic (〈2 mm) in 8 (73%). Other symptoms included rhinorrhea in eight (53%), dyspnea or tightness of the chest in four (27%), and cough in two (13%). Atropine sulfate was given to six, and pralidoxime was given to one of these six doctors. To decontaminate the emergency room of sarin vapor, ventilation was facilitated and all belongings of the patients were sealed up. None of the doctors noticed worsening of their symptoms thereffter. Conclusions Careful attention to the risks of secondary exposure to toxic gas in the emergency room and prompt decontamination if such exposure should occur are necessary in the case of large-scale disasters caused by sarin.