Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (2)
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 70 (1999), S. 1713-1718 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The dynamics and noise of a dc superconducting quantum interference device (SQUID) with the McCumber parameter βc=2πR2IcC/Φ0 close to the unity (where Ic, R, C are the critical current, the shunt resistance, and the capacitance of the Josephson junctions comprising the SQUID, respectively, and Φ0=2.07×10−15 Wb is the magnetic flux quantum) integrated with a planar spiral input coil have been experimentally studied. The length of the spiral input coil was chosen to match its λ/4 microwave resonance frequency to the plasma resonance frequency of the SQUID. The input coil resonance enhances the overall quality factor Q of the Josephson oscillations in the SQUID and, as a result, increases the dynamic resistance Rd and the gradient of the flux-to-voltage characteristics ∂V/∂Φ without hysteresis. This relaxes the tolerance for the βc parameter, simplifies the technological process, and improves the yield of devices. A dc SQUID with loop inductance L=31.4 pH, βc=0.72, and a six turn input coil has demonstrated a nondistorted quasisinusoidal flux-to-voltage transfer function with an exceptionally large modulation depth of approximately 140 μV peak-to-peak. A spectral density of the intrinsic magnetic flux noise as low as 3.5×10−7 Φ0/Hz1/2 has been measured in the double stage configuration at a temperature of 4.2 K using direct read-out electronics. This corresponds to the intrinsic energy resolution of ε=12.5h. In combination with an intermediary transformer, the current resolution of the SQUID is as low as 1.25 pA/Hz1/2 with an input coil inductance of 58 nH. The coupled energy resolution is εc=45h in the white noise region. © 1999 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 68 (1997), S. 1461-1464 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A novel miniature superconducting quantum interference device magnetometer with direct readout electronics has been developed. A high flux-to-voltage transfer factor of up to 2500 μV/Φ0 is achieved without additional positive feedback (Φ0 is the flux quantum). A flux resolution of 8×10−7 Φ0/Hz1/2, corresponding to a magnetic moment sensitivity of approximately 2×10−20 A m2/Hz1/2, has been measured. This magnetometer can be used to study the dynamic magnetization properties (including nuclear magnetic resonance and magnetic resonance imaging) of micron and submicron size particles and for high-resolution surface magnetometry. © 1997 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...