Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1990-1994  (4)
  • 1980-1984
  • Bone  (2)
  • Speed-of-sound  (2)
  • 1
    ISSN: 1433-2965
    Keywords: Bone ; Bone fluoride content ; Calcification defects ; Osteoporosis ; Sodium fluoride treatment
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Fluoride treatment is used to increase bone formation and cancellous bone mass in patients suffering from postmenopausal osteoporosis with vertebral fractures. Patients submitted to similar therapeutic protocols have shown various histological responses to the treatment, some developing calcification defects and others not. In fact, the bone histological response to fluoride salts depends on the cumulative uptake of fluoride by bone. To clarify the relationship between the presence of calcification defects (identified by the presence of mottled bone and linear formation defects) and the bone fluoride content, a retrospective study was performed on 29 women with type 1 osteoporosis and treated for several months (11–24) with sodium fluoride (50 mg/day), calcium and vitamin D. Bone fluoride content always significantly increased after treatment, but it was significantly higher in patients showing calcification defects than in those having no defects. These differences between the two groups of patients were not due to differences in clinical details (no significant differences concerning age, duration of treatment, total amount of fluoride ingested, renal function) or in their bone remodelling activity. Thus, it may be hypothesized that the high bone fluoride uptake is due to different individual responses from one patient to another concerning the bioavailability of the same dose of fluoride. This is difficult to predict, except by testing the individual bioavailability of the compound to be used in each patient before starting long-term treatment.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1433-2965
    Keywords: Bone ; Histomorphometry ; Osteoporosis ; Osteoblasts ; Osteocalcin
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract To assess the bone turnover abnormalities which characterize postmenopausal osteoporosis with vertebral fractures (PMOp), a transiliac bone biopsy was performed after double labeling of the mineralizing front with tetracycline in 50 untreated PMOp patients who were compared with 13 healthy age-matched volunteer females. The analysis of bone remodeling and structure parameters demonstrated that PMOp is a disease affecting both the cancellous and the endocortical envelopes and characterized by increased resorption and by a marked decrease in the osteoblastic apposition rate due to a reduced duration of bone formation. This induces a decrease in the width of both individual osteons and trabeculae. In PMOp, the wide spectrum of bone turnover as compared with the controls, associated with the typical bimodal distribution of cancellous osteoid perimeter, allowed us to identify two subsets, one with normal turnover (NT) and one with high turnover (HT) representing 30% of the cases. When compared to NT, HT was characterized by increased osteoclast number, lower bone volume, thinner osteons, increased formation at the tissue-level and markedly decreased duration of formation. In HT the marked decrease in the duration of activity of osteoblasts and the markedly increased number of osteoclasts induced a greater decrease in bone volume, despite the increase of bone formation at the tissue level. These subsets could not be distinguished by any clinical or biochemical parameter except for serum bone gla protein (osteocalcin) which was significantly higher (as a group) in HT than in NT. The underlying cause for these two subsets is unknown. We conclude that PMOp affects the cancellous and the endocortical bone. Bone loss results from a wide spectrum of bone turnover abnormalities, with two distinct subsets, one with normal turnover and one with high turnover.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 54 (1994), S. 91-95 
    ISSN: 1432-0827
    Keywords: Fat ; Ultrasound attenuation ; Speed-of-sound ; Os calcis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Abstract Measurements of the speed-of-sound (SOS) and of the broadband ultrasound attenuation (BUA) on the os calcis were recently proposed to assess osteoporotic fragility. Velocity and attenuation were measured through the heel which can be divided in three phases including hydroxyapatite, soft tissue, and fat. The aim of this study was to evaluate the influence of fat composition and heel width on SOS and BUA. This influence was determined from both in vitro investigations examining fat samples, phantoms, and cadaver heels, and in vivo ones observing adult volunteers as well as a wide sample section of healthy elderly women. Ultrasound velocities on various fat samples were significantly lower than those on distilled water (-65 m/second to -123 m/second). The excision of the surrounding soft tissue from cadaver heels made SOS steadily increase whereas the insertion of a 10 mm piece of lard in the lateral face of cadavers' and volunteers' heels os calcis lowered SOS about 30 m/second. ond. Furthermore, a difference of SOS was estimated at 15 m/second for a 12.5% variation of the marrow fat weight. Among 334 elderly and healthy women aged 75 and over, a significant negative correlation was found between SOS and heel width (r=-0.27; P〈0.0001). On the other hand, fat composition had no significant effect on BUA measurement, and no significant relationship was found between BUA and heel width. This study demonstrates that an increase of heel width and fat thickness provides an underestimation of os calcis SOS, but has no significant effect on BUA.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1432-0827
    Keywords: Broadband ultrasound attenuation ; Speed-of-sound ; Stiffness index ; Interunit precision
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Abstract Ultrasonic assessment is a new approach to assess both quality and density. Two ultrasonic parameters are measured on the os calcis: the attenuation or broadband ultrasound attenuation (BUA) and the velocity or speed of sound (SOS). The interunit variations in vitro and in vivo of an ultrasound instrument, the Lunar AchillesR system, used in a French multicenter study named EPIDOS, were calculated and the stability of these intruments over a 12-month period was evaluated. A third parameter called “stiffness index”, calculated from the SOS and BUA, was also used in this study. The average CV in vitro for the BUA and SOS was 0.92% and 0.12%, respectively, and the average CV in vivo for the BUA, the SOS, and the stiffness index was 1.83%, 0.23%, and 1.9%, respectively. The interunit (or inter-machines) variations were calculated by a one-way analysis of variance. We detected small but significant measurement differences among centers on a phantom for both SOS (maximum significant difference 0.4%) and stiffness (maximum significant difference 3.5%) but not for BUA. Similar diffrences were found in vivo. The precision over 12 months of the interunit variations in vitro was evaluated by measuring a single phantom traveling from one center to another several times. The range of the CV for the BUA (1.54–0.51%), for the SOS (0.25–0.14%), and for the stiffness index (2.26–1.10%) are explained in part by technical failures. The variation among the five Achilles was estimated by the combined CV which was 1.42% for the BUA, 0.32% for the SOS, and 2.33% for the stiffness index. In conclusion, our findings indicate that equipment from one manufacturer appears to be consistent between machines for the BUA, but not completely for the SOS. The results for this stiffness index are necessarily influenced by both SOS and BUA. The shortterm and long-term interunit precision is good, both in vitro and in vivo. Such results provide increased confidence in multicenter clinical trials where ultrasonic data are pooled.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...