  • 1
    ISSN: 0952-3499
    Keywords: Cytokine ; Receptor ; Biosensor ; Titration ; Calorimetry ; Association rate ; Dissociation rate ; Equilibrium analysis ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A surface plasmon resonance (SPR) biosensor was used to study the interaction of human interleukin-5 (hIL5) with its receptor. IL5 is a major growth factor in the production and activation of eosinophilis. The receptor for IL5 is composed of two subunits, α and β. The α subunit provides the specificity for IL5 and consist of an extracellular soluble domain, a single transmembrane region and a cytoplasmic tail. We expressed the soluble domain of the human IL5 receptor α subunit (shIL5Rα) and human IL5 (hIL5) in Drosophila. Both hIL5 and shIL5Rα were immobilized separately through amine groups onto the carboxylated dextran layer of sensor chips of the BIAcore™ (Pharmacia) SPR biosensor after N-hydroxysuccinimide/carbodiimide activation of the chip surface. Interactions were measured for the complementary macromolecule, either shIL5Rα or hIL5, in solution. Kinetics of binding of soluble analyst to immobilized ligand were measured and from this the association rate constant, dissociation rate constant and equilibrium dissociation constant (Kd) were derived. With immobilized shIL5Rα and soluble hIL5, the measured Kd was 2 nM. A similar value was obtained by titration calorimetry. The Kd for Drosophila expressed receptor and IL5 is higher than the values reported for proteins expressed in different systems, likely due to differences in the methods of interaction analysis used for differences in protein glycosylation. Receptor-IL5 binding was relatively pH independent between pH 6.5 and 9.5. Outside this range the dissociation rate increased with compressibility little increased in association rate. The values obtained for the interaction of hIL5 and shIL5Rα were found to depend on which component was immobilized; the Kd was 5.5 nM with immobilized hIL5 and soluble shIL5Rα. The SPR biosensor provides a unified methodology to measure the interaction properties of shIL5Rα and hIL5 derivatives, mutants and mimetic as well as to evaluate potential antagonists of the receptor-cytokine interaction.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1040-0397
    Keywords: Biosensor ; Glucose ; Nafion ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A glucose-sensitive electrode composed of glucose oxidase (GOX) embedded in a layer of the polymer Nafion is described. Electrodes of various configurations on which the layer was cast were tested to determine their response to glucose additions to phosphate buffer and human whole serum samples. These electrodes have good response characteristics and several desirable features. Glucose sensors based on Nafion/GOX layers cast onto platinum electrodes respond to glucose additions with a rapid response time (2 to 4 seconds), have a long lifetime when stored in a phosphate buffer (55 days before termination of testing), have a reduced sensitivity to local oxygen tension, respond linearly to additions of glucose to the serum, and are not fouled by exposure to blood. The Nafion confers some permselectivity on the layer, thus providing a degree of discrimination against anioni interferents.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...