Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1990-1994  (1)
  • 1965-1969  (6)
  • Chemistry  (6)
  • (Z)-8-tetradecenyl acetate and (Z)-8-tetradecenyl alcohol  (1)
  • 1
    ISSN: 1573-1561
    Keywords: Lepidoptera ; Tortricidae ; Spilonota ocellana ; eye-spotted bud moth ; sex pheromone ; (Z)-8-tetradecenyl acetate and (Z)-8-tetradecenyl alcohol
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Abstract Response of male eye-spotted bud moth,Spilonota ocellana (Denis and Schiffermüller), to different ratios of synthetic sex pheromone components, (Z)-8-tetradecenyl acetate (Z8-14:OAc) and (Z)-8-tetradecenyl alcohol (Z8-14:OH), were compared in four North American locations and in one location in The Netherlands. In British Columbia, Nova Scotia, Michigan, and The Netherlands, a 99:1 blend ofZ8-14:OAc andZ8-14:OH captured significantly more maleS. ocellana thanZ8-14:OAc alone or binary blends containing 10–50%Z8-14:OH. In Ontario, where population sizes were low compared to the other four locations, trends in trap catches were similar, and there was no indication that maleS. ocellana responded differently to the tested pheromone blends. A 99:1 blend ofZ8-14:OAc andZ8-14:OH should be most effective in pheromone-based control programs ofS. ocellana in North America and in The Netherlands. Our results confirm earlier studies that a 99:1 blend ofZ8-14:OAc andZ8-14:OH captures significantly more maleS. ocellana thanZ8-14:OAc alone. However, our finding that a 99:1 blend ofZ8-14:OAc andZ8-14:OH is significantly more attractive than binary blends containing 10–50%Z8-14:OH differs from previous findings in Germany and Switzerland.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 11 (1967), S. 1851-1854 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Use of porous glass with a broad pore-size distribution as a column packing for gel permeation chromatography has been investigated. The porous glass is readily available, and columns are packed easily and have excellent mechanical stability. Separations of polystyrene over molecular weight ranges of 500-2,000,000 have been obtained. Porous glass thus appears to be a useful packing material for gel permeation chromatography.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 12 (1968), S. 1373-1377 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Sensitive refractive index measurements on solutions have indicated that the narrow molecular weight polystyrene samples prepared by the Mellon Institute method exhibit a small systematic molecular weight-refractive index dependence up to 300,000 and higher. This upper limit is higher than had previously been suggested. Sensible consistency is generally assumed above a few thousand molecular weight. The effect on this molecular weight-refractive index dependence on gel permeation chromatography and light-scattering molecular weight measurements on polystyrene standards is illustrated.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 8 (1966), S. 135-151 
    ISSN: 0006-3592
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Foam separation of microorganisms has been investigated with varying success by many workers, usually at high rates of gas flow. Microflotation was developed to overcome some of the disadvantages inherent in these high gas-flow-rate processes and is introduced in this paper as a new technique for the foam separation of microorganisms at low gas-flow rates. With microflotation, a stable surface phase is produced by adding an insoluble collector such as a long-chain fatty acid or amine. The formation of an insoluble surface phase eliminates the need for high foaming. Low rates of gas flow are used resulting in a more efficient separation and a less voluminous and drier surface phase upon which to collect the microorganisms. The efficiency of this technique is also improved by using flotation aids such as frothers and flocculents. Frothers are used to improve the collector properties of the surfactant and to refine further the small bubbles produced by a very fine sparger. Small concentrations of flocculents, such as alum, are used to partially agglomerate the organisms and provide sites for adsorption of collector. The work described in this paper is preliminary in nature, designed to illustrate that a low flow-rate process may be used to separate microorganisms and to stimulate further research. The applications discussed are removal of the bacterium, Escherichia coli, and alum, and two species of algae, Chlamydomonas reinhardtii and Chlorella ellipsoidea, using stearylamine without alum. The frother used was ethanol.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 12 (1966), S. 1026-1026 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Zeitschrift für die chemische Industrie 78 (1966), S. 609-609 
    ISSN: 0044-8249
    Keywords: Chemistry ; General Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science Part A: General Papers 3 (1965), S. 833-846 
    ISSN: 0449-2951
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: Preparation of a carboxylic ion-exchange membrane by grafting poly(acrylic acid) onto cellophane is described. This membrane filters appreciable fractions of dissolved salt from solutions 1M and less in NaCl; flow rates through the membrane at 2500 psi are 0.5 cm./hr. and higher. Comparison is made of salt rejection properties and flow rates with a film of cellulose acetate in which rejection does not depend on fixed ionizable groups. Rejections of salts having ions of different charges are presented. Experimental apparatus for hyperfiltration is described.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...