Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1990-1994  (2)
  • 31.30.Gs  (1)
  • Measurement techniques: magnetic resonance imaging; infrared telemetry  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Journal of clinical monitoring and computing 8 (1992), S. 37-43 
    ISSN: 1573-2614
    Keywords: Monitoring: heart, respirations ; Measurement techniques: magnetic resonance imaging; infrared telemetry
    Source: Springer Online Journal Archives 1860-2000
    Topics: Computer Science , Medicine
    Notes: Abstract A system for patient monitoring during magnetic resonance imaging (MRI) is described. The system is based on remote auscultation of heart sounds and respiratory sounds using specially developed pickup heads that are positioned on the precordium or at the nostrils and connected to microphones via polymer tubing. The microphones operate in a differential mode outside the strong magnetic field to reduce various sources of interference from the MRI equipment. After amplification, the signal is transmitted as infrared light to a small, battery-operated receiver and a headphone set. Thus, the patient can be simultaneously auscultated both inside and outside the shielded MRI room by infrared transmission through a metal mesh window. Bench tests of the system show that common mode acoustic noise is suppressed by approximately 30 dB in the frequency region of interest (100–1,000 Hz), and that polymer tubing having a diameter of approximately 2 mm can be used for efficient sound transmission. Recordings in situ show satisfactory detection of both heart sounds and respiratory sounds, although the signal is somewhat masked by noise during imaging. A clinical test incorporating 17 sedated or anesthetized patients was also performed. In all but four cases, the quality of the breath and heart sounds was regarded as acceptable or better.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 18 (1991), S. 107-112 
    ISSN: 1434-6079
    Keywords: 21.10.Ft ; 31.20.Ej ; 31.30.Gs
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract By means of classical interference spectroscopy, using enriched isotope samples, the isotope shift between178Hf and180Hf has been measured for 33 transitions in the Hf II spectrum. For the pure Russell-Saunders terms 5d 26s 4 F and2 F the parametric analysis yields a field-shift difference of 17(2) mK produced by the second-order interaction of the electrostatic operator and the field-shift operator. Semi-empirical calculations based on the non-relativistic Hartree-Fock method reproduce this value as well as the experimental field shifts if a factor of 1.68(6) is used to scale theab initio electron densities at the nucleus. The corresponding factor for the Hf atom is much smaller. This leads to a re-evaluation of screening ratios for Hf and to a more accurate value of the nuclear parameter λ178,180 (Hf)=0.072(4) fm2.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...