Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1990-1994  (2)
  • 34.80 D  (1)
  • Radiation dose  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 52 (1991), S. 336-340 
    ISSN: 1432-0649
    Keywords: 34.80 D ; 41.80 Dd ; 42.55 F
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract In order to study the kinetic mechanism of the e-beam pumped Ar/Xe laser, the temporal profiles of individual laser lines during multiline oscillation have been measured as a function of power deposition (1–12MW/cm3) and gas laser pressure (2–14 bar) using a short pulse (30 ns) coaxial electron beam as excitation source. It was found that the optimum output energy at each pressure was obtained at the same specific power deposition. Strong line competition has been observed between the 2.65 and 1.73 μm transitions. In order to explain our results we suggest that besides electron collision mixing (ECM) between the 5d and 6p levels of Xe, there is also a redistribution between all 6p levels which strongly favours the lower levels at higher pumping densities.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1084
    Keywords: Chest ; Digital storage phosphor radiography ; Intensive care ; Neonates ; Radiation dose
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract In order to evaluate the influence of radiation exposure on image quality in digital storage phosphor radiography, 200 digital storage phosphor chest radiographs, obtained on a neonatal Intensive Care Unit, and the same number of conventional screen-film radiographs (speed 250) were assessed for the visibility of anatomical structures and catheters. The same exposure parameters were used in both groups. Normal variations of radiation exposure under free exposure conditions were estimated in all digital images using a formula calculating radiation dose in the screen-plane from image sensitivity, latitude and average grey value of the right lung. There was already a significant (P 〈 0.001) decline in image quality in the digital images with a 30–50% reduction in radiation exposure, which was most severe for structures such as trachea, retrocardiac space, lung texture and low-contrast catheters. Compared with optimally exposed conventional images, only those digital images with a slightly higher than normal dose had an equivalent image quality.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...