Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1990-1994  (2)
  • Acute respiratory failure  (1)
  • Bronchodilator agents  (1)
  • Pulmonary mechanics  (1)
  • 1
    ISSN: 1432-1238
    Keywords: Status asthmaticus ; Artificial respiration ; Magnesium sulfate ; Bronchodilator agents
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract In severe status asthmaticus basic medical treatment often fails to improve the patient's condition. Mechanical ventilation in this situation is associated with a high incidence of serious complications. After the bronchodilating effect of moderate-dose magnesium sulfate in asthmatic patients had been demonstrated in previous studies we treated five mechanically ventilated patients with refractory status asthmaticus successfully with high dosages of MgSO4 IV (10–20 g within 1 h depending on the bronchodilating effect). MgSO4 resulted in a significant decrease of peak airway pressure (43.0±6.8 to 32.0±8.0 cmH2O) and inspiratory flow resistance (22.7±7.0 to 11.9±6.0 cmH2O·l−1·s−1) within 1 h. The resulting serum magnesium levels after one hour were up to threefold of the normal serum levels. Although a main-tainance dose of 0.4 g/h had been administered continuously during the following 24 h serum magnesium decreased towards normal values within this time. The only relevant side-effect was a mild to moderate arterial hypotension in two of the five patients during the high dose administration period of MgSO4 which responded readily to dopamine treatment.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1238
    Keywords: Static compliance ; Pressure volume curve ; Pulmonary mechanics ; Acute respiratory failure ; Adult respiratory distress syndrome
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A new method for determination the static compliance of the respiratory system is described (“static compliance by automated single steps”-SCASS). In 12 ventilated patients pressure/volume (P/V) curves were determined by automated repetitive occlusion (6 s) at single volume steps and compared to the conventional syringe method (SM). All measurements were corrected for effects of temperature, humidity and pressure (THP). SM was found to be significantly influenced by intrapulmonary gas exchange causing an effective mean volume deficit of 217.4±65.7 ml (BTPS) at the end of the deflation. In contrast to that, the short duration of occlusion in SCASS minimize the gas exchange effects. The methodical differences between both methods result in overestimation of the inflation compliance in the uncorrected SM (SMuncorr: 83.4±12.6; SCASS: 76.0±11.9 ml/cmH2O.p〈0.01) and underestimation of the deflation compliance resp. (SMuncorr: 58.3±7.5; SCASS: 79.1±15.0 ml/cmH2O.p〈0.005). In contrast to the P/V curves by SM no significant hysteresis was found by SCASS. Gas exchange seems to be the main reason for the hysteresis. Even after correcting gas exchange and THP effects a significant hyseresis remained. The SCASS method avoids these problems and allows furthermore an accurate checking of leaks.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...