Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 0935-6304
    Keywords: Capillary GC ; On-line extractive alkylation ; On-line acylation ; Carboxylic acids ; Amines ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Gas chromatographic procedures are described for the determination of carboxylic acids and chlorinated anilines in water samples.Propionic acid and 2,6-difluorobenzoic acid in aqueous solution have been simultaneously alkylated and extracted by means of a continuous two-phase reaction system, and then quantitated by on-line coupled capillary gas chromatography; tetrahexyl-ammonium hydrogen sulfate was used as phase transfer catalyst and pentafluorobenzyl bromide as reagent.A factorial design approach was used to optimize on-line derivatization of aqueous propionic acid with regard to pH and concentration of phase transfer catalyst. Alkylation and extraction, under optimized conditions, followed by quantitation of the pentafluorobenzyl ester by flame ionization detection furnished a linear calibration for concentrations between 0.1 and 10 μg/ml. The relative standard deviation was 9-15 %.The continuous two-phase reaction system was also used to determine (chlorinated) anilines present in water at concentrations of 0.1-1 μg/ml; pentafluorobenzoyl chloride was used as reagent and analysis was performed by capillary gas chromatography with flame ionization or electron capture detection. The on-line acylation of p-chloroaniline was optimized with regard to pH, reagent concentration, and reaction time.The on-line reaction system worked satisfactorily for both applications, although excess reagent caused some problems with the chromatography.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Microcolumn Separations 5 (1993), S. 303-315 
    ISSN: 1040-7685
    Keywords: capillary GC ; solid phase extraction ; membrane disks ; water samples ; automation ; nitrogen-phosphorus detection ; mass selective detection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: An automated procedure for the analysis of aqueous samples by membrane disk extraction coupled on-line to capillary gas chromatography (GC) is presented. Organophosphorus pesticides are preconcentrated from aqueous samples on three 0.5 mm thick, 4.0 mm diameter XAD-2 membrane extraction disks which are mounted in a polymer holder for use in a PROSPEKT sample processor. The layers are dried by a stream of nitrogen (30 min at ambient temperature). Desorption of the analytes is carried out with ethyl acetate which is directly introduced into a retention gap under partially concurrent solvent evaporation conditions, using an early solvent vapor exit. The method is a fully software-controlled automated system, and includes sample preparation, sample transfer and GC analysis. The final analysis is carried out by GC with nitrogen-phosphorus (NPD) or mass-selective detection. The technique is applied to the determination of a series of organophosphorus pesticides in tap water and water from European rivers. With a sample volume of only 2.5 mL, the detection limits achieved with the NPD were 20-50 ng L-1 in tap water and 20-100 ng L-1 in river water.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...