Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1990-1994  (28)
  • Polymer and Materials Science  (17)
  • Analytical Chemistry and Spectroscopy  (9)
  • mass spectrometry
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    The protein journal 9 (1990), S. 623-632 
    ISSN: 1573-4943
    Keywords: Pancreatic thread protein ; primary structure ; mass spectrometry
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract Pancreatic thread protein (PTP) forms double helical threads in the neutralpH range after purification, undergoing freely reversible,pH-dependent globule-fibril transformation. The purified bovine PTP consists on SDS gels of two carbohydrate-free polypeptide chains (Grosset al., 1985). Plasma desorption mass spectrometry and amino acid sequence analysis now confirm that bovine PTP contains two disulfide-bonded polypeptides, an A chain of 101 amino acid residues with a molecular weight of 11,073 and a B chain of 35 residues with a molecular weight of 3970. The intact protein exhibits a molecular weight of 15,036, agreeing 〉99.9% with the molecular weight calculated from the sequence. The B chain sequence was determined by gas-phase Edman degradation of the intact polypeptide. The A chain sequence was determined from overlapping peptides generated by cleavage at lysyl, tryptophanyl, and aspartyl-prolyl residues. Based upon the bovine PTP cDNA structure, the two chains of the protein result from cleavage of a single polypeptide with removal of a dipeptide between the NH2-terminal A chain and COOH-terminal B chain. Comparison of bovine PTP with other proteins reveals significant structural relatedness with the single-chain homologues from human and rat pancreas and with the motif associated with Ca2+-dependent carbohydrate recognition domains. The physiological role of PTP has not yet been resolved. The protein is present in very high concentration in pancreatic secretion and it has been detected in brain lesions in Alzheimer's disease and Down syndrome and in regenerating rat pancreatic islets. The present results provide a firm protein base for ongoing molecular, physical-chemical, and structure-function studies of this unusual protein.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part A: Polymer Chemistry 29 (1991), S. 169-186 
    ISSN: 0887-624X
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The semicontinuous seeded emulsion copolymerization of vinyl acetate and methyl acrylate was investigated. The effect of type of process (starved process versus semi-starved process), type of feed (neat monomer addition versus monomer emulsion addition), amount of seed initially charged in the reactor, and feed rate on the time evolution of the overall conversion, copolymer composition, and polymer particle size was analyzed. It was found that, in the case of the starved process, both monomers, but mainly vinyl acetate, accumulated in the reactor. The preferential accumulation of vinyle acetate resulted in a drift of the copolymer composition. Both monomers accumulation and copolymer composition drift were reduced by increasing the amount of seed initially charged in the reactor and by decreasing the feed rate. For the semi-starved process, it was found that a vinyl aceatate rich copolymer was formed when a low methyl acrylate feed was used, whereas a methyl acrylate rich copolymer was obtained at high methyl acrylate feed rates. For both starved process and semi-starved process, the total number of polymer particles, after an initial increase, reached a plateau value which was the same in all of the experiments carried out. These results were analyzed by means of a mathematical model developed for this system.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 0935-6304
    Keywords: Supercritical fluid chromatography ; Supercritical fluid extraction ; Poly(vinyl chloride) ; Dimethyltin mercaptide ; Formic acid ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0935-6304
    Keywords: Capillary GC ; Petroleum crude oil ; Condensates ; Carbon number distribution ; Pseudocomponents ; Quality control ; Quality assurance ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A quality control scheme has been developed to achieve reproducible capillary GC characterization of crude oils and petroleum condensates. The method uses an internal standard to quantify the amount of non-eluted material in the crude oil sample. Correlation between the gas chromatographic results and actual distillation was 2 %. After repeated use, however, weekly analysis of the same standard crude oil did not give the correct composition. This was a result of discrimination, which worsened with time, as a result of leaks in the septum or the graphite ferrules. More reproducible results were obtained by performing frequent analyses of quality control samples to ensure that the gas chromatographic system was operating properly. The use of quality control charts was a convenient way of ensuring correct operation and identifying the need for corrective action on the gas chromatographic system.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 16 (1993), S. 130-134 
    ISSN: 0935-6304
    Keywords: Supercritical fluid chromatography ; Packed columns ; Modifiers ; Formic acid ; Formamide ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Quantification of 1-O-alkyl-2-lyso-sn-3-glycero-phosphocholine (lysoPAF) and determination of the different molecular species released by cells has been hampered by the molecules's lack of intrinsic bioactivity, unavailability of a suitable internal standard, and reliance on derivatives requiring electron impact techniques. We have synthesized trideuterated internal standards (labeled on the terminal carbon of the alkyl chain) for both C16:0 and C18:0 lysoPAF. Using these standards, we isolated and quantified lysoPAF released from A23187-stimulated human neutrophils and rat alveolar macrophages. Extracted lysoPAF was purified by solid-phase extraction and thin-layer chromatography. The polar phosphorylcholine group was removed with 29 M HF or phospholipase C. The two free hydroxyl groups were derivatized with pentafluorobenzoyl chloride. The resultant bis-pentafluorobenzoyl derivative, analyzed by gas chromatography/electron capture negative ion mass spectrometry, underwent substantial fragmentation. Lowering of the ion source temperature resulted in a dramatic increase in signal-to-noise ratio, with the vast majority of the ion current carried in the molecular anion. Stimulated neutrophils released 16.3 and 10.2 ng/106 cells of C16:0 lysoPAF and C18:0 lysoPAF, respectively. Rat macrophages synthesized 15.9 ng/106 cells of C16:0 lysoPAF, but C18:0 lysoPAF was variably detected at low levels. We conclude that use of the bispentafluorobenzoyl ester derivative of lysoPAF allows facile quantification of this autacoid metabolite in biological matrices.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The use of precursor ion and constant neutral loss scanning as a means of rapidly detecting drug metabolites is evaluated. Four clinically useful drugs, namely (i) cyclophosphamide, (ii) mifentidine, (iii) cimetropium bromide and (iv) haloperidol, were subjected to microsomal incubations to afford phase I metabolites. Aside from a minor clean-up procedure involving zinc sulfate precipitation of microsomal proteins and solid-phase extraction of metabolites using a Sep-pak C-18 cartridge, the mixtures were analysed directly by fast atom bombardment tandem mass spectrometry. It is demonstrated that such screening strategies are important in detecting novel metabolites. However, there are some problems associated with only using such methods, including (i) the possibility of not detecting metabolites that undergo unusual collision-induced dissociation fragmentation pathways, (ii) the non-detection of metabolites that have undergone metabolic change at unusual sites of reactivity, and (iii) production of artifacts derived from the parent drug by the primary ionization process. Examples are discussed that highlight both the strengths and weaknesses of such an approach.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Mass spectrometry has played a key role in characterizing the primary structure of native and recombinant relaxin, a peptide hormone that induces ripening of the cervix prior to childbirth. The peptide is composed of two chains, A and B, and is formed from a single-chain prohormone, as is insulin. Aside from conserved cysteines, though, it has little sequence homology with insulin. Due to the small amounts of native peptide initially available ( 〈 10 pmol), traditional techniques could not provide information on the blocked A-chain sequence, on the carboxy-terminal sequences, nor on other possible post-translational modifications. Mass measurements by fast atom bombardment (FAB) were made on reduced human relaxin isolated from corpora lutea. The detection limit by FAB for reduced relaxin was 500 fmol. The B-chain was four amino acids shorter than expected from comparison of the previously known cDNA sequence with homologous rat and porcine sequences. The A-chain, as predicted, was 24 amino acids in length and had a pyroglutamic acid residue on the amino-terminus. The purified samples were homogeneous with no other post-translational modifications. The recombinant relaxin molecule was also extensively characterized by mass spectrometry. In addition to the intact molecule, all tryptic peptides were characterized by FAB. A capillary high-performance liquid chromatography continuous-flow FAB system, developed for high-sensitivity peptide mapping, aided in these analyses. Finally, the three disulfide bonds were shown by tandem mass spectrometry to match those of insulin.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1042-7147
    Keywords: Silk ; Mechanical ; Spider ; Silkworm ; Thermal ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Dragline silk from the spider, Nephila clavipes, was characterized by thermal analysis (TGA, DSC, DMA), computational modeling, scanning electron microscopy and by quasi-static as well as high rates of strain. Thermal stability to about 230°C was observed by TGA, two transitions by DMA, -75°C, representative of localized motion in the amorphous domain, and a main chain motion associated with partial melt at 210°C. Tensile tests indicated average initial modulus, ultimate tensile strength and ultimate tensile strain of 22 GPa, 1.1 GPa and 9%, respectively. The corresponding properties of the best fibers tested were 60 GPa, 2.9 GPa and 11%, respectively. High strain rates (〉50,000%/sec) indicated similar mechanical properties to the average values indicated above. Microscopy showed compressive and tensile strains to failure of 34%. Computational modeling yielded a crystal modulus of 200 GPa.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Polymer International 34 (1994), S. 81-88 
    ISSN: 0959-8103
    Keywords: poly(acrylic acid) ; poly(vinyl phosphonic acid) ; glass polyalkenoate cement ; polymer blend ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Physical blends of spray-dried poly(acrylic acid), PAA, with poly(vinyl phosphonic acid), PVPA, have been prepared and used in experimental dental cements by mixing them with basic sub-45 μm acid-degradable fluoroaluminosilicate glass powders and adding water. The effect of varying the ratio of PAA to PVPA, of altering the molar mass of PAA, and of using glasses of differing basicity have been investigated. The compressive strengths of the best of the cements formed from these blends were comparable to those formed from the individual polyacids, i.e. about 160 MPa.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...