Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1041
    Keywords: Dosage frequency ; Compliance ; drug-intake behaviour ; oestrogen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The objective of the study was to investigate patient compliance with two different dosage regimens. Ethinyloestradiol 80 μg daily was prescribed to 35 female outpatients to be taken as 20 μg four times daily or 40 μg twice daily for 7 days. It was given to standardise cervical mucus before a sperm cervical mucus penetration-test (SCMPT) was performed. Sixty-five patients with primary infertility (mean age 29.9 y) completed the study. Compliance was assessed by microprocessor-based compliance monitoring. Besides compliance (percentage of prescribed doses taken), the adherence of the patients to the dosage schedule was evaluated — ‘regimen compliance’. The latter parameter of drug intake behaviour was calculated by the number of days in which 2 (BID) or 4 openings (QID) were recorded by the electronic monitor. As a third parameter, the deviation from the prescribed dosing intervals, i.e. 12 or 6 h, was also determined. Partial compliance was the predominant finding and only 9 patients (13.8%) were over-compliant. Mean compliance was 75.7% in all 65 patients as a group, range 7.1 to 143%. The mean compliance with the QID regimen was 67% compared to 85% with the BID regimen. ‘Regimen compliance’, the percentage of doses taken on schedule, was 36% and 63% for the QID and BID regimens, respectively. Drug-intake behaviour was more erratic with the QID than the BID regimen, as indicated by the 55% of opening intervals recorded which exceeded the range of 3–9 h (mean: 6 h), compared to only 19% exceeding 6–18 h intervals (mean: 12 h). The present study provides evidence that the prescribed dosage frequency has an impact on drug compliance by patients. From a practical point of view, it seems reasonable to use treatment regimens that are as simple as possible, provided that they are pharmacologically and clinically appropriate.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal für Praktische Chemie/Chemiker-Zeitung 335 (1993), S. 235-243 
    ISSN: 0941-1216
    Keywords: Chemistry ; Organic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: New Macrocyclic Hosts for the Inclusion of Organic Guest Molecules - Crystal Structure of a Complex with Dimethylformamide (1 : 1)New pyridino crowns with amide and sulfonamide groups 1b and 1c are synthesized. They form numerous stoichiometric crystalline inclusion complexes with alcohols, various dipolar-aprotic solvents, as well as cyclic ethers. Host-guest stoichiometries are discussed and inclusion selectivities (relating to DMF) are shown. The structure of the crystalline DMF inclusion compound of the sulfonamide host 1c (1 : 1) is determined by X-ray diffraction, showing a lattice void inclusion mode.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    Surface and Interface Analysis 15 (1990), S. 583-584 
    ISSN: 0142-2421
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The detection limit of Auger electron spectroscopy (AES) can be improved by mathematical methods that reduce the influence of noise. We compared principal component analysis (PCA) and spline smoothing and applied them to the analysis of a phosphorus depth profile in silicon. Both methods yield similar results under typical conditions, namely detection limits of ∼0.04 at.% P compared with a limit of 0.09 at.% for the raw data. At a reduce signal-to-noise ratio, the PCA failed and the improvement by smoothing remained constant.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...