Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1990-1994  (4)
  • Chemistry  (2)
  • Impedance plethysmography  (2)
  • 1
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part B: Polymer Physics 30 (1992), S. 293-297 
    ISSN: 0887-6266
    Keywords: poly(p-phenylene) from organometallic polymerization, crystal structure of ; crystal structure of poly(p-phenylene) from organometallic preparation ; X-ray diffraction of organometallically produced poly(p-phenylene) ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: The two-dimensional crystal structure of poly(p-phenylene) is investigated by linkedatom Rietveld analysis of the x-ray diffraction powder profile. Two molecular chains are packed in a rectangular pgg unit cell (a = 0.779 nm; b = 0.551 nm) with a paracrystalline shift distortion along the chain axis. The molecular conformation is not rigidly planar; rotations between adjacent phenyl-ring planes in a molecule alternate with an angle of about 20°. The setting angle between the mean molecular plane and the a axis is 55.5°.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 29 (1991), S. 419-424 
    ISSN: 1741-0444
    Keywords: Blood flow in human limbs ; Disk electrode ; Electrode system ; Impedance plethysmography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract Electrode design and electrode positioning are important factors in blood flow measurements using impedance plethysmography. Optimal electrode type and accurate positioning will decrease measurement errors and improve the signal-to-noise-ratio. Disk electrodes were found to be superior to tape electrodes because of their better skin-electrode stability and because they prevent limb compression. The distance between current electrodes and potential electrodes should be greater than 2·3 R (disk electrodes) and 1·5 R (tape electrodes) to avoid the influence of the so-called diffusion resistance (R is the radius of the limb at the electrode site).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 30 (1992), S. 518-524 
    ISSN: 1741-0444
    Keywords: Blood flow in human limb ; Cross-sectional area ; Impedance plethysmography ; Strain gauge
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract The cross-sectional area of a limb varies along the extremity. This is of great importance when impedance plethysmography is used for limb blood flow studies. The actual measurement site, as well as the interelectrode distance, must be carefully selected to avoid underestimation of the blood flow value. The distance between the potential electrodes should be less than 10 cm for an adult subject.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 47 (1993), S. 2207-2216 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: To improve oil and water repellency, fluorine-containing block copolymers, which were composed of methyl methacrylate (MMA), glycidyl methacrylate (GMA), and 1H, 1H, 2H, 2H-heptadecafluorodecyl acrylate (PFA), were blended with an epoxy resin. It was expected that a glycidyl group would mesh with the epoxy resin by primary bonding, and the low surface energy fluorocarbon segment would absorb and orient to the exterior to fluorinate the surface. X-ray photoelectron spectroscopy, contact angle, and peel strength of pressure-sensitive adhesives for modified epoxy resin surface were determined. The amount of fluorine obtained via angular-dependent ESCA investigation in the modified resin surfaces increased with the shallowing of the sampling depth. With increasing modifier content, the amount of fluorine in the modified resin surface layer increased, and the critical surface tension of modified resin surfaces and the peel strength of a silicone pressuresensitive adhesive affixed to the modified epoxy resin, decreased. A considerable amount of fluorine in the resin surface modified with GMA-containing block copolymers remained after Soxhlet extraction, whereas in the surface modified with copolymer without GMA, more fluorine was extracted. It was extracted. It was shown that these copolymers were good surface modifiers to improve oil and water repellency. © 1993 John Wiley & Sons, Inc.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...