Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1990-1994  (3)
  • Polymer and Materials Science  (2)
  • Integrated electromyography  (1)
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Advanced Materials for Optics and Electronics 2 (1993), S. 313-318 
    ISSN: 1057-9257
    Keywords: MOCVD ; MAS-NMR ; CARS ; Quantum effects ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: Coherent anti-Stokes Raman scattering (CARS) has been utilised to monitor the decomposition of trimethylgallium (TMGa) on the reactive internal surface of the protonated form of zeolite Y under metal organic chemical vapour deposition (MOCVD) conditions designed to produce GaP deposits that exhibit quantum-size effects. The CARS data clearly reveal the facile room temperature decomposition of TMGa in the zeolite, as evidenced by the detection of increasing levels of methane with increasing reaction time. In addition, the zeolite samples were analysed by solid state nuclear magnetic resonance with magic angle spinning (MAS NMR) before reaction, after reaction of TMGa and after subsequent reaction with phosphine at 300°C. These data reveal that TMGa reacts with acid sites in the zeolite 12-rings, resulting in species containing methyl groups. Subsequent exposure to phosphine removes these methyl group protons, leaving various, as yet not fully characterised, phosphorus species. Exposure to phosphine does not appear to regenerate the acid sites on the zeolite.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    European journal of applied physiology 69 (1994), S. 508-515 
    ISSN: 1439-6327
    Keywords: Integrated electromyography ; Mean power frequency ; Lactate threshold ; Ventilatory threshold ; Treadmill running
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract This study analysed the changes in electromyographic (EMG) activity of the vastus lateralis, biceps femoris and gastrocnemius muscles during incremental treadmill running. The changes in EMG were related to the lactate and ventilatory thresholds. Ten trained subjects participated in the study. Minute ventilation, oxygen consumption, carbon dioxide expired and the fraction of oxygen in the expired gas were recorded continuously. Venous blood samples were collected at each exercise intensity and analysed for lactate concentration. The EMG were recorded at the end of each exercise intensity using surface electrodes. The EMG were quantified through integration (iEMG) and by calculating the mean power frequency (MPF). The iEMG measurements were characterized by a breakpoint in the vastus lateralis and/or gastrocnemius muscles in eight of the subjects tested. However, the results indicated that blood lactate concentrations had already begun to increase in a nonlinear fashion before the iEMG breakpoint had been surpassed. Consequently, the occurence of the lactate threshold cannot be attributed solely to the change in motor unit recruitment or rate coding patterns demonstrated by the iEMG breakpoint. The ventilatory threshold was shown to be a far more reliable and convenient noninvasive predictor of the lactate threshold in comparison with EMG techniques. In conclusion, the EMG measurements used in this study (i.e. iEMG and MPF) were not considered to be viable noninvasive determinants of the aerobic-anaerobic transition phase in treadmill running.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 0142-2421
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The surface composition of various ceramic substrates used for electronics applications is heterogeneous. In the case of debased alumina, this may result from the diffusion of sintering aids such as silica, added during the manufacturing process, which produce a complex bonding surface. In this study, the durability of a visible light curing resin applied to a variety of ceramic substrates of differing acidity/basicity was investigated. Butt-joints consisting of photocured resin adhered to quartz, silicon wafers and polished alumina were produced. Following immersion in water at 50°C for periods of several weeks, joints were fractured (in situ in the VG ESCALAB Mk II and just prior to loading into the Scienta ESCA300). Angle-resolved XPS analysis was carried out on both sides of the failure. Failure occurred cohesively, with 1-2 nm of polymer remaining on the ceramic side of the failure. Orientation of the oxygenated functional groups of the polymer was observed within this overlayer, with methoxy groups being aggregated immediately adjacent to the inorganic surface; subtle differences were observed between the polished alumina and other substrates. An absence of the aromatic groups from the photocured polymer was also noted on the ceramic side of the failure. These results are explained in terms of acid-base interactions, and a model for adhesion and subsequent failure of the system is proposed.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...