Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1990-1994  (2)
  • Nicardipine  (1)
  • Technetium-99m labelled human serum albumin  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    European journal of pediatrics 152 (1993), S. 712-714 
    ISSN: 1432-1076
    Keywords: Nicardipine ; Children ; Hypertension
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Fourteen hypertensive patients hospitalized in a paediatric intensive care unit were studied to evaluate safety and hypotensive efficacy of intravenous nicardipine. Systolic and diastolic blood pressure significantly decreased 1 h after the beginning of the treatment (1 μg/kg per minute). Mean decrease in systolic blood pressure during the first 24 h was between 9.9% and 13.4% of the initial value. Mean lowering of diastolic blood pressure was between 16.7% and 25.6%. Nicardipine did not significantly affect heart rate with dose of 1 μg/kg per minute. No clinical side-effects were observed. Nicardipine could be a first line drug for the treatment of hypertension in paediatric intensive care units.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1619-7089
    Keywords: Technetium-99m labelled human serum albumin ; Labelling kit ; Ventriculography ; Blood pool agent
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract In this study we have compared the characteristics of six labelling kits for the preparation of technetium-99m labelled human serum albumin (99mTc-HSA) and evaluated the usefulness of the various 99mTc-HSA preparations as blood pool tracer agents. The amount of the principal ingredients, i.e. HSA and stannous ions, varies largely between the studied kits and this is probably a reason for the observed differences in the labelling rate. Analysis of the reaction mixtures after labelling of the respective kits with 99mTc showed in each preparation the presence of four to five radioactive components in variable relative amounts. The retention time of the main component on size-exclusion high-performance liquid chromatography (SEC-HPLC) was identical for all preparations. Biodistribution of the HPLC-isolated fractions was studied in mice. The components with the shortest and longest retention times on HPLC show poor retention in the plasma. The three intermediate fractions, including the principal peak, are initially retained relatively well in the blood (60%–70% of the injected dose after 10 min), but clearly to a lower degree than iodine-125 labelled HSA. Moreover, they diffuse out of the vascular compartment at a much higher rate than 125I-HSA. The biological behaviour of the main component of the various preparations was clearly different, despite the identical retention time on SEC-HPLC. Study of the total preparations in mice and a rabbit showed that two of them are cleared rapidly from the blood and cannot be considered valuable blood pool tracers. Diffusion of the other preparations out of the blood is slower but also considerable and compromises their use for ventriculography.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...