Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1990-1994  (3)
  • Polymer and Materials Science  (3)
Material
Years
Year
Keywords
  • 1
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 25 (1991), S. 515-523 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: We have previously studied a large number of histological specimens of biomaterials and found that regions with and without an intervening fibrous membrane coexisted in many specimens. Therefore, it appears necessary to perform an evaluation of the entire specimen when histologically assessing the affinity of bone for a biomaterial. Accordingly, we performed a quantitative histological evaluation of hydroxyapatite (HAP)- and titanium- oxide(TiO2)-coated Ti-6Al-4V and uncoated Ti-6Al-4V (control) by determining the affinity index. This was defined as the length of bone directly opposed to the implant/the total length of the bone--implant interface X 100%. The test materials were inserted into the distal epiphyseal region of the femurs of adult dogs, and follow-up quantitative histological comparisons were performed from 4 weeks to 96 weeks. The HAP-coated implants had the highest affinity index 4 weeks after insertion, and this superiority was maintained up to 96 weeks. There was a significant difference in affinity index between HAP-coated implants and control implants (P 〈 0.001), while TiO2-coated implants showed no significant difference in comparison to the control.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 27 (1993), S. 557-563 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The interface shear strength of uncoated Ti-6Al-4V, dense sintered hydroxyapatite (HA), and HA-coated Ti-6Al-4V were compared. Interface shear strength was determined using a transcortical push-out model in dogs 4 and 12 weeks after implantation. The interface shear strength of dense sintered HA and HA-coated Ti-6Al-4V was significantly higher than that of uncoated Ti-6Al-4V (P 〈 .001). There was no significant difference between the interface shear strength of dense sintered HA and HA-coated Ti-6Al-4V. After the push-out test for HA-coated implants, the regions fractured at the bone-coating interface and at the coating-titanium interface coexisted at 4 weeks after implantation. At 12 weeks, the fracture site was, in all cases, the HA coating-titanium interface, and, in a few samples, fractures inside the coating layer also were visible. © 1993 John Wiley & Sons, Inc.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 24 (1990), S. 1111-1113 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...