Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1990-1994  (2)
Material
Years
Year
  • 1
    ISSN: 1573-9325
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Abstract Results are presented of examination of the effect of a constant polarizing field of the mechanical strength of PKR-67 anisotropic piezoceramic material developed at the Scientific Research Institute of Physics at the Rostov State University. The strength of disk piezoelements in tensile loading was evaluated by the coaxial bending method. An increase of the strength of the constant polarizing field resulted in a nonmonotonic reduction of the mechanical strength limit. This variation of the mechanical strength limit is determined by the nonstationary nature of the processes of formation and growth of microcracks as a result of interaction of these microcracks with the rearranged domain structure and defects. In the field strength range Ep=(6–8)·106 V·m−1 it was possible to produce sufficiently strong piezoceramics with unique combination of the main electrophysical parameters.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Measurement techniques 36 (1993), S. 816-818 
    ISSN: 1573-8906
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Notes: Abstract The construction and operation of a lead zirconate-titanate (TsTS-19) piezoelectric transducer as a component of the model UZR-V ultrasonic flowmeter with an Akustron counter is analyzed. Techniques are proposed for enhancing the operating efficiency of ultrasonic flowmeters. The study has resulted in the development of the UZD-1 and UZD-3 transducers, which utilize the new materials and have parameters superior to those of a standard transducer using TsTS-19 ceramic. The new transducers are recommended for systems designed to monitor cold and hot water flow in conduits from 30 mm to 1000 mm in diameter.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...