Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Analytical chemistry 54 (1982), S. 332-334 
    ISSN: 1520-6882
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 59 (1986), S. 71-79 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: In the magnetized plasma of a hollow cathode arc the longitudinal and rotational drift velocities of ions have been measured, together with the electron and neutral densities and the temperatures of ions, electrons, and neutrals. The radial and longitudinal gradients of these quantities have been established. The ions drift against the electric field towards the anode with velocities between about 500 and 2500 m/s, driven by the plasma pressure gradient which is balanced by viscous deceleration and by friction against the surrounding neutral gas. The classical theory of the momentum balance with a turbulent contribution to the viscosity provides a good description of the longitudinal ion transport and explains direction and magnitude of the occurring drift velocity.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 57 (1986), S. 3075-3080 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A user-selectable, multimode, beta-ionization cell has been developed for gas chromatographic (GC) detection. The system consists of a modified dc current (nonpulsed) electron capture cell enclosed in a stainless-steel vacuum chamber. A gas mixing manifold connected to the input of the detector enables various reagent gases to be mixed with the GC effluent prior to entering the detector cell. Simply by varying the pressure of the reagent gas inside the detector from atmospheric to as low as 50 mTorr, one of four different modes of operation can be achieved. These include (1) conventional electron capture detection (atmospheric pressure), (2) cross-section ionization electron emission (〈1 Torr), (3) low-pressure argon ionization electron emission (1–10 Torr), and (4) mixed electron capture/electron emission (100–300 Torr). One advantage of this detector is the ability to switch between selective detection (electron capture) and universal detection (argon ionization) by only changing the operating pressure in the cell. Another important feature is that the degree of selectivity is continuously tunable in the mixed electron capture/electron emission mode of operation. This is due to a dramatic pressure dependent competition between argon ionization electron emission and capture of near-thermal electrons by compounds passing through the detector. This selectivity appears to be strongly related to the electron affinity of compounds, with those exhibiting the highest electron affinities capable of capturing electrons at the lowest pressures. This enables classes of compounds, such as polychlorinated biphenyls (PCBs), to be detected in the presence of hydrocarbons. Additionally, compounds such as isomeric polycyclic aromatic hydrocarbons (PAH) can be readily distinguished using this detector.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1089-7666
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Collective scattering of CO2 laser light on electrons is used to determine the radial scale length of the discharge structures occurring in a closed cycle magnetohydrodynamic generator. Hetero- dyne detection of scattered radiation is used to obtain a spatial resolution in the submillimeter range and to increase the signal to noise ratio. A discharge model is formulated to interpret the measured signals. The scale length of the electron density fluctuations is found to be (2.5±0.5) ×10−4 m.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of chemical & engineering data 26 (1981), S. 396-398 
    ISSN: 1520-5134
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Palo Alto, Calif. : Annual Reviews
    Annual Review of Sociology 7 (1981), S. 157-175 
    ISSN: 0360-0572
    Source: Annual Reviews Electronic Back Volume Collection 1932-2001ff
    Topics: Sociology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Copenhagen : International Union of Crystallography (IUCr)
    Applied crystallography online 15 (1982), S. 15-19 
    ISSN: 1600-5767
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Geosciences , Physics
    Notes: The forward scattering of cold neutrons in small-angle scattering experiments on macromolecules dissolved in mixtures of light and heavy water is predominantly determined by the large incoherent cross section of the hydrogen atoms leading to an isotropic background level. The probability per unit solid angle for forward scattering by samples rich in H2O is approximately equal to the fraction of the primary beam which has not been transmitted through the sample, divided by the full solid angle 4π. When using the camera D11 at the high flux reactor in Grenoble [Ibel (1976). J. Appl. Cryst. 9, 296–309] this simple relation is fulfilled within ±5% by a 1 mm thick sample of H2O at 281.8 K using neutrons of 1.0 nm wavelength. In D2O, the coherent cross section is of the same order as the incoherent one, and about one half of all those neutrons which had been removed from the primary beam are scattered into large angles. Our experimental results and the derived graphs allow us to determine the effective forward scattering per unit solid angle for any volume fraction of D2O in H2O/D2O mixtures around room temperature by a simple and accurate transmission experiment in conjunction with the measurement of the scattering of one single sample of H2O of 1 mm thickness, for neutrons of wavelengths from 0.45 to 1.0 nm.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Copenhagen : International Union of Crystallography (IUCr)
    Applied crystallography online 14 (1981), S. 191-202 
    ISSN: 1600-5767
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Geosciences , Physics
    Notes: The present study presents the first small-angle neutron scattering experiment of lipid bilayers in excess water. The method of solvent contrast variation was applied. The variation of scattering intensity with the scattering angle could be analysed in terms of the Kratky–Porod model of scattering by quasi-two-dimensional systems. From this the bilayer thickness of unilamellar vesicles of dimyristoyllecithin was determined to be d = 41 ± 1 Å at 310 K. Several typical mixtures of different lecithins with varying chain lengths and of lecithin with phosphatidic acid were studied. By deuteration of one lipid component a very large contrast between segregated phases could be achieved. It was thus possible to distinguish clearly between homogeneous mixtures and mixtures which exhibit a heterogeneous lipid organization. In the latter case no intensity matching upon solvent contrast variation was possible. It is shown that phase boundaries may be determined very accurately by performing contrast variation experiments with at most two mixtures of different initial composition. The main advantage of the present method is that lateral phase separation may also be clearly studied in fluid states of the bilayer. From the average scattering-length densities one can determine the density of the lipid layers and thus the excess volumes of the mixtures. For lecithin mixtures positive excess volumes are observed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Scandinavian journal of immunology 26 (1987), S. 0 
    ISSN: 1365-3083
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The CD4 molecule, which is known to play an important role in the susceptibility of T lymphocytes to infection by the human immunodeficiency virus (HIV), is also expressed in small amounts on the surface of monocytes. Since monocytes can also be infected by the virus, we investigated peripheral blood monocytes of patients with the acquired immunodeficiency syndrome (AIDS). AIDS-related complex (ARC), and HIV seropositive and seronegative haemophiliacs without symptoms for the expression of the CD4 molecule and for other functionally important surface molecules such as CD11 (C3bi receptor), transferrin receptor, Fc receptor, and the three major histocompatibility complex (MHC) class II antigens HLA-DP. HLA-DR, and HLA-DQ. With immunofluorescence staining and flow cytometry no difference was found between patients and controls for the expression of the CD4 molecule and for the other antigens as assessed by the percentage of positive staining and the specific fluorescence intensity in a double marker analysis. The percentage of CD4+ monocytes was found to be 59.2±14.4% for 16 patients with AIDS and 52.9±12.8% for 12 healthy controls. Similar to our results on phenotype, we found no significant difference with respect to the production of tumour necrosis factor (TNF), in that monocytes of AIDS and ARC patients showed an increase in TNF secretion after stimulation with LPS comparable to controls.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Archives of gynecology and obstetrics 242 (1987), S. 423-424 
    ISSN: 1432-0711
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...