    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 21 (1987), S. 367-377 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Wear-accelerated corrosion rates at constant anodic potentials were evaluated for unimplanted and nitrogen-ion-implanted surgical Ti-6Al-4V while wearing against ultrahigh-molecular-weight polyethylene at stress levels up to 6.90 MPa (1000 psi). The ion implantation processing was found to reduce the wear corrosion rates in both saline and serum solutions at all applied stress levels. During wear testing, all of the ion-implanted surfaces remained visually unchanged from the polished condition. However, many of the unimplanted surfaces developed damage zones characterized by wear tracks and black wear debris. A surface-damage mechanism is proposed and discussed which involves disruption of the Ti-6Al-4V protective oxide film, subsequent entrapment of oxide particles in the polyethylene, then self-perpetuating damage due to the abrasive action of the embedded particles.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 21 (1987), S. 355-366 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The influence of nitrogen-ion implantation on the wear-accelerated corrosion behavior of surgical Ti-6Al-4V was studied. Non-passivated and prepassivated unimplanted Ti-6Al-4V specimens were employed as controls for comparison. Corrosion rates as a function of time at open-circuit corrosion potentials were electrochemically measured in saline and serum solutions under both static and wear conditions. The wear parameters simulated those of a total artificial hip under average walking conditions. The results indicated that prepassivation of the control material was beneficial under static-corrosion conditions, but not under wear-corrosion conditions. The nitrogen-ion implantation process was found to significantly improve the material's resistance to wear-acceler-ated corrosion in both saline and serum solutions.
    Additional Material: 7 Ill.