Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 11 (1988), S. 761-766 
    ISSN: 0935-6304
    Keywords: Gas chromatography, GC ; GC/MS ; Sampling ; PAH ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Samples were taken of the atmospheric particulate matter over Fairbanks Alaska in the winter of 1985, and from wood stoves burning the major wood types locally available. These samples were then analyzed for polycyclic aromatic hydrocarbon (PAH). A PAH emission profile was determined from the wood stove samples and applied to the atmospheric samples to determine the residential wood combustion contribution to the local atmospheric particulate burden. Emission profiles for coal burning and automobile emissions for PAH were also used to estimate their relative contributions.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 8 (1985), S. 595-601 
    ISSN: 0935-6304
    Keywords: Gas chromatography, GC ; Sequentially coupled capillary columns ; Stationary phase selectivity ; Effective capacity factors ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: This investigation lays groundwork for the development of an optimization system for sequentially coupled capillary column systems. Three methods for calculating effective capacity factors were obtained from the literature and were tested to determine suitability for optimization use, using four test analytes and two dissimilar columns. This work concentrates on the development of a method for the estimation of optimum column temperatures in sequentially coupled systems.
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 12 (1989), S. 821-824 
    ISSN: 0935-6304
    Keywords: Multidimensional gas chromatography ; Capillary gas chromatography ; Liquid-crystalline stationary phase ; Polychlorinated biphenyls ; PCB ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 12 (1989), S. 669-674 
    ISSN: 0935-6304
    Keywords: Supercritical fluid chromatography ; Capillary columns ; Injection techniques ; Reproducibility ; Sensitivity ; In-line dual detection ; Explosives ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The reproducibility of peak areas as a function of the technique used for sample injection was investigated in capillary supercritical fluid chromatography (SFC). An injection technique has been developed to increase the volume of sample introduced into the capillary column. Using a modified time-split injection technique, long injection duration times were successfully applied to achieve lower detection limits. Analytes were effectively focused at the head of the analytical column using a unique pressure trap program. Because this on-column focusing was performed only by pressure and temperature programming, no instrumental modifications were necessary. Up to 1.0 μL of sample solution was injected onto 50 μm i.d. columns using this technique, with no observable peak splitting. Dual detection using ultraviolet (UV) absorption and flame ionization detection (FID) was performed in series, thereby avoiding the necessity of splitting the column effluent. For the compounds investigated (five nitroaromatics and one phthalate ester), the absolute sensitivity of the UV detector was significantly greater than that of the FID.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...