Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1985-1989  (2)
  • 1965-1969
  • Gas chromatography  (1)
  • Klebsiella pneumoniae  (1)
  • 1
    ISSN: 1432-072X
    Keywords: F1F0 ATP synthase ; Escherichia coli ; Klebsiella pneumoniae ; Phylogenetic relationship
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Abstract The ATP synthase complex of Klebsiella pneumoniae (KF1F0) has been purified and characterized. SDS-gel electrophoresis of the purified F1F0 complexes revealed an identical subunit pattern for E. coli (EF1F0) and K. pneumoniae. Antibodies raised against EF1 complex and purified EF0 subunits recognized the corresponding polypeptides of EF1F0 and KF1F0 in immunoblot analysis. Protease digestion of the individual subunits generated an identical cleavage pattern for subunits α, β, γ, ε, a, and c of both enzymes. Only for subunit δ different cleavage products were obtained. The isolated subunit c of both organisms showed only a slight deviation in the amino acid composition. These data suggest that extensive homologies exist in primary and secondary structure of both ATP synthase complexes reflecting a close phylogenetic relationship between the two enterobacteric tribes.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 27 (1989), S. 221-224 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Large volume sample injection ; Closed on-column injector
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A new simplified version of a “closed” on-column injector is introduced. Because of its design isobaric injection conditions do not have to be followed and a wide range of injection temperatures above the boiling point of the sample solvent can be chosen for on-column injections in capillary gas chromatography. Also, when following certain basic injection rules, injections of large sample volumes (≥20 μl or more) give accurate and reproducible results without further problems.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...