Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1106
    Keywords: Vestibular instrumentation ; Methodology ; Spacelab-1 mission ; Hardware ; Microgravity research
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary A series of vestibular experiments were performed in conjunction with the first Spacelab mission, consisting of sets of pre-, in- and postflight tests. A multipurpose experimental apparatus used for the diverse flight and ground tests is presented. Additional apparatus together with the multi-purpose package were used in the baseline data collection facility at the landing site at NASA Dryden Flight Research Facility for the ground tests. The tests involved optokinetic, caloric and mechanical (whole-body or head-alone) stimulation. The latter included linear acceleration in the subject's x, y and z axes, static roll and yaw about an earth-vertical axis. Physiological parameters such as electro-oculogram (EOG), blood-volume-pulse (BVP), respiration, as well as the stimulus variables such as acceleration and caloric temperature were transmitted to the ground and recorded there. The flight and ground testing schedules are outlined. Problems arising from this complex venture are discussed, and some suggestions are made for future improvement.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Journal of neurology 233 (1986), S. 16-18 
    ISSN: 1432-1459
    Keywords: Spinal cord stimulation ; Chronic pain ; Electrodes ; Psychopathology
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary A total of 50 patients with chronic pain syndromes were selected for treatment with spinal cord stimulation. Correct positioning of electrodes was obtained in 44 patients, leading to an initial alleviation of pain in 25 patients. In 6 patients, electrodes (though still effective in 4) had to be removed because of surgical complications within the first 5 months of use. Only 8 patients had at least some beneficial effect lasting for more than 3 years. The long-term results in patients with more severe psychological disturbances were no worse than those of the other patients.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...