Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Oxidation of metals 29 (1988), S. 487-497 
    ISSN: 1573-4889
    Keywords: Alloy ; oxidation ; platinum ; palladium ; rhodium
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Abstract The surfaces of Pt-45Pd-10Rh foils oxidized over the range 875–1075 K in a 20% O2-Ar mixture at atmospheric pressure were examined by Auger electron, X-ray photoelectron, and Raman spectroscopy. The composition of the oxide formed on the surface was found to vary with temperature from predominantly PdO at 875 K to PdRhO2 at 1075 K. Only a few atomic percent Pt was observed, present in both the metallic and (apparently) +1 oxidation states at 875 K and in the metallic state at 1075 K. The formation of PdRhO2 (and no Rh2O3) at 1075 K was found to persist upon reoxidation following a low-temperature reduction cycle in which the increased Rh concentration on the surface was retained. An oxidation-induced Rh enrichment of the surface of the alloy foil beyond 50 at. % does not appear likely within the temperature/pressure regime investigated.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Bioluminescence and Chemiluminescence 1 (1986), S. 47-51 
    ISSN: 0884-3996
    Keywords: ATP ; luciferin-luciferase ; bioluminescent assay ; HLA-typing ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: The amount of adenosine triphosphate (ATP) in human lymphocytes was determined using a technique based on light emission from a bioluminescent reaction with luciferin-luciferase. The amount of ATP changed when cells were incubated in the presence of specific HLA antisera and complement. For determination of intracellular ATP a modified method was applied, which was based on reduction of extracellular ATP by the addition of ATPase. The results of titration of an anti-human lymphocyte serum using the bioluminescence assay were in agreement with the results of fluorescence vitality staining. Bioluminescent HLA-determination in 57 cell samples each tested with 5 different antisera also gave good agreement (95.8%) with the conventional method. From these experimental data the calculated ATP content per lymphocyte was 0.135 ± 0.058 pg ATP.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...