Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1985-1989  (2)
  • 25.70. Lm  (1)
  • Polymer and Materials Science  (1)
  • 25.40.Sc
  • Nuclear reactions
Material
Years
Year
Keywords
  • 1
    ISSN: 1434-601X
    Keywords: 25.70. Lm
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The element distributions for the reactions32S+100Mo,32S+93Nb, and28Si+93Nb have been measured atE/B∼1.4. The correlations between the first moment of the measured distributions and TKEL are consistent with the predictions of the liquid drop potential energy surfaces showing the charge equilibration of the dinuclear systems. The measured second moments are compared with a recent systematics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 22 (1988), S. 445-457 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Cylinders (0.8 cm long, 1.0 cm of diameter and with an axial hole), constituted, after firing, of a ceramic mixture of hydroxylapatite (HA) and β-ricalciumphosphate (β-TCP) in a 10:1 ratio, were implanted into mid-diaphiseal defects of one femur of 20 rabbits and stabilized with intramedullary rods. The implantation sites were checked radiographically every month, and after 3 months (3 animals) and 6 months (17 animals) the rabbits were sacrificed and the implants with the surrounding tissue were embedded in methylmetacrylate, cut to thick sections and analyzed by scanning electron microscopy (SEM). Porosimetric and x-rays diffraction analyses were carried out before and after implantation of the cylinders, and the state of mineralization at the bone-implant interface was determined by EDAX microprobe analysis. Bony callus formation started at 1 month at the osteotomy sites, as judged by radiography, but after 3 months a not-mineralized zone had still been demonstrated between bone and the implants. At 6 months, 13 implants showed themselves firmly fixed in their implantations beds, while 4 implants were only incorporated at their proximal ends. In bone contact zones, an enrichment of Ca2+ was displayed by microanalytical techniques in the outer zone of the implanted samples which may be explained by an apparent additional phase transformation of HA into TCP, thanks to the change of the Ca/P ratio, that takes place in vivo.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...