Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1985-1989  (3)
  • Analytical Chemistry and Spectroscopy  (3)
  • Carbon disulfide
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 12 (1989), S. 89-95 
    ISSN: 0935-6304
    Keywords: Gas chromatography, GC ; Injector design ; Splitless injection ; Injector overflow ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Injector overflow is determined quantitatively by analysis of the septum purge effluent. Vaporizing chambers must have an internal volume of about 1 ml (e.g. 80 × 3.6 mm i.d.). This allows splitless injection of volumes between 1 and 2.5 μl, depending on the solvent. The septum purge should be closed during splitless transfer to prevent losses by back-diffusion.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 12 (1989), S. 49-50 
    ISSN: 0935-6304
    Keywords: Coupled LC-GC ; Olive oil ; Erythrodiol ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 12 (1989), S. 591-598 
    ISSN: 0935-6304
    Keywords: On-line coupled LC-GC ; Partially concurrent eluent evaporation ; Early vapor exit ; Retaining pre-column ; Irradiated fat ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: This paper reports two subjects. It describes LC-GC transfer by partially concurrent eluent evaporation at a greatly accelerated rate, as required for optimal compatibility with 2-3 mm i.d. LC columns and LC flow rates up to some 500 μl/min. Evaporation rates around 200 μl/min were obtained using a 0.53 mm. i.d. uncoated pre-column and an early vapor exit. A stationary-phasecoated “retaining” pre-column was used for preventing escape of volatile solutes through the vapor exit.The technique was used for the detection of food irradiation by analyzing selected radiolysis products of triglycerides, namely alkanes/alkanes and aldehydes. Extracted fat of chicken, hazel-nuts, and soup mixes was injected in LO and the relevant fractions were transferred on-line to GC. For chicken and nuts, detection of irradiation was possible down to doses below 0.5 kGy. Detection limits were higher for soup mixes due to interfering peaks.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...