Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1985-1989  (2)
  • Anion-exchange stationary phases  (1)
  • Cross-linked polystyrene  (1)
  • 1
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Anion-exchange stationary phases ; Polymer coating ; Cross-linking
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary PHEB=POLY(2-hydroxy, 3N-ethylenediamino)butadiene has been synthesized. This unsaturated pre-polymer can be immobilized on different, preferably inorganic supports of suitable porosity such as silica or alumina by cross-linking. Weak anion-exchange phase are obtained. Such phases do not have the disadvantages of organic polymeric phases, regarding pressure stability and swelling by solvent influence. The ion-exchange capacity and the retentivity of IE-separations can deliberately be varied via the thickness of the cross-linked polymer layer. Alumina can also be coated with PHEB applying the same cross-linking procedure. Such phases exhibit an exceptional chemical stability even when operated with mobile phases at very high pH-values. Separations of excellent selectivity are achieved for inorganic anions, as well as with mixtures of aliphatic and aromatic free acids also including hydroxy- (mono- or poly)carboxylic acids.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Cross-linked polystyrene ; Characterization of surfaces
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The properties of the poly(styrene-divinylbenzene) copolymers PRP-1 and PLRP-S have been studied by infrared spectroscopy and chromatographic techniques. The following results were obtained: PRP-1 and PLRP-S are spectroscopically very similar. Their surfaces are chemically neither homogeneous nor stable during use. Retained nonpolar solutes should be eluted with a mobile phase containing tetrahydrofuran. Uncharged acids and anions can be chromatographed without difficulty. Cations of amines should be chromatographed only with a mobile phase of low pH. Uncharged amino-alcohols cannot be chromatographed without the addition of a competitor.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...