  • 1985-1989  (4)
  • Chemical Engineering  (2)
  • radiometry  (2)
  • 1
    ISSN: 1436-5073
    Keywords: interferometry ; spectroscopy ; Fourier transform ; atmospheric remote sensing ; radiometry
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract An aircraft version of the high-resolution interferometer sounder (HIS), a Fourier transform spectrometer designed for meteorological applications, has been used to measure the upwelling infrared emission of the earth with a resolving power on the order of 1000. HIS measurements from high-altitude NASA research aircraft have demonstrated that the high radiometric accuracies required for atmospheric temperature and humidity sounding (1°C absolute brightness temperature and 0.1° C RMS reproducibility) can be achieved. Calibration is accomplished using periodic views of two onboard high-emissivity blackbodies, servo controlled to 300 K and 240 K. For an interferometer, this approach relies on careful optical design and alignment to avoid unknown dependence of the responsivity on optical path difference. The aircraft model is a successful prototype for spacecraft versions for weather and climate monitoring.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1436-5073
    Keywords: atmospheric spectra ; radiometry ; cryogenic instruments
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract The SCRIBE (Stratospheric CRyogenic Interferometer Balloon Experiment) system was flown August 10, 1986, over eastern New Mexico. Because the SCRIBE sensor is a liquid nitrogen cooled interferometer, absolute radiance data were obtained with good resolution (0.1 cm−1) and high sensitivity. The normal field of view was reduced to ~0.2° (80 m on the ground) by a 12′' Dall-Kirkham telescope, and was steered by remote control using television cameras boresighted with the infrared sensor. The stabilized viewing allowed “staring” at selected features for considerable periods of time. The data sets thus include spectra of different terrain features, as well as substantially different atmospheric paths to one feature. Both the data and the SCRIBE equipment are described.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 25 (1985), S. 896-902 
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Mixtures of 90, 80, and 70 percent by weight bisphenol-A-polycarbonate (PC) and 10, 20, and 30 percent by weight styrene maleic anhydride (SMA) copolymer were melt-blended in a single screw extruder. Differential scanning calorimetry (DCS) and scanning electron microscopy (SEM) were used to determine the miscibility of the blends. The viscosity, as a function of shear rate and temperature, was measured by an Instron capillary viscometer. The notched impact strength as a function of temperature was measured by an Izod impact tester.The results of DSC showed two glass transition temperatures which merged slightly towards each other, indicating marginal miscibility of these blends. There was a decrease in viscosity as the fraction of SMA copolymer was increased. The most significant decrease occurred with the initial addition of SMA copolymer. The viscosity also decreased with increases in temperature. The impact strength of the blends was also dependent on SMA copolymer content. The blends showed six to ten times lower impact strengths at room temperature than the 100 percent polycarbonate. SEM analysis helped to determine the reason why the impact strength was lower for the blends. High magnification showed the presence of SMA copolymer inclusions dispersed throughout the PC matrix. These inclusions, which increased in size as SMA copolymer content was increased, acted as defects in the system.
    Additional Material: 16 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Plant/Operations Progress 6 (1987), S. 1-5 
    ISSN: 0278-4513
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Experience indicates that machinery vibration monitoring programs are most effective when planned in accordance with carefully established program goals and objectives. Methods are presented to determine the appropriate monitoring program for a given plant, key issues to address in program planning, and proven techniques for successfully implementing the program.