Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Microcolumn Separations 1 (1989), S. 136-141 
    ISSN: 1040-7685
    Keywords: MECC ; nucleotide ; SDS ; HTAB ; DTAB ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A high-speed separation of the mono-, di-, and triphosphorylated common ribonucleosides has been explored using micellar electrokinetic capillary chromatography (MECC). Retention behavior in terms of electroosmotic flow, peak capacity (to/tmc) and resolution can be manipulated by the choice of surfactant type and the concentration in the buffer phase. The relative effects of an anionic surfactant, SDS, and two cationic surfactants, DTAB and HTAB, were explored and optimized to produce an effective separation of the solutes.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Organic Magnetic Resonance 27 (1989), S. 841-845 
    ISSN: 0749-1581
    Keywords: Polychloroazanaphthalenes ; Multiple substituent chemical shifts ; MSCS ; NIMS ; 13C predictions ; Molecular orbital charge calculations ; CNDO/2 calculations ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Three methods, two empirical and one semi-empirical, for predicting 13C chemical shifts in six poly-chloroheterocyclics are considered. It was found that the semi-empirical correlations with CNDO/2 calculated charges, although useful, could not be used in isolation from the other two methods. Of these, the MSCS (multiple substituent chemical shifts) method could be used to predict all eighteen carbon shifts in perchloroquinoline and perchloroisoquinoline, whilst the NIMS method (hypothetical nitrogen insertion method) was limited to the carbons in the heterocyclic ring. In brief, it was found that the MSCS method was the most accurate (less than ± 1 ppm) for predicting chemical shifts, intrinsically compensating for some of the errors arising from mutual atom-atom interactions.New 13C data are reported for heptachloroquinoline, a mixture of two polychloroquinolines, hepta-chloroisoquinoline and two, separable, new polychloroisoquinolines.
    Additional Material: 3 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...