Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Clinical Anatomy 2 (1989), S. 17-27 
    ISSN: 0897-3806
    Keywords: wrist position influence ; fast isometric contractions ; motor control ; human hand muscles ; Life and Medical Sciences ; Miscellaneous Medical
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: The influence of wrist position on the motor control of intrinsic and extrinsic hand muscles during the performance of fast isometric precision-grip contractions was evaluated. Ten male and female subjects, aged 17-28 years, attempted to produce accurately 75%, 50%, 25%, and 10% of a predetermined maximum criterion force level with the wrist in the flexed, functional, and extended positions. Feedback on the accuracy of each contraction was provided by a visual error display after each trial. Trials selected for analysis fell within ± 5% error of the required force level. Surface electromyograms were recorded from the first dorsal interosseous, adductor pollicis, abductor pollicis brevis, common flexor muscles and the extensor digitorum. Wrist position was shown to influence significantly the integrated electromyographic values representing the activity of the first dorsal interossous but not the adductor pollicis. Significant alterations in the onset time of the antagonist extensor digitorum were also detected. On the basis of the these results we suggest that the intrinsic muscles of the hand can be classified as either wrist position dependent or independent.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    European journal of applied physiology 58 (1988), S. 132-140 
    ISSN: 1439-6327
    Keywords: Motor control ; Motor skill ; Electromyography ; Inaccuracy ; Isometric
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The aim of this study was to investigate the electromyographical basis of inaccurate movement by identifying the variate and invariate characteristics of a ballistic, isometric precision-grip skill. Our results have shown that in most subjects investigated, IEMG, discharge rate and the paterns of muscle synergy were variate movement parameters while the sequence of muscle activation, the relative duration of muscle activity and the time to peak force (rise-time) remained essentially invariante. Based on these results, we can conclude that inaccurate performance of this skill, in most of the subjects investigated, was more dependant upon changes in muscle IEMG than in alterations in the temporal sequencing of muscle activity. It was apparent that from trial to trial, subjects had more difficulty in reproducing the appropriate levels of muscle contraction and synergy than in reproducing the required periods of action.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...